Intramedullary plugs in total hip arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
8
0
3

Year Published

1995
1995
2007
2007

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 11 publications
1
8
0
3
Order By: Relevance
“…We have shown that the Thackray polyethylene plug (Fig. 1) has a failure rate of at least 25%, and this has been confirmed by others (Bakker et al 1988;Northmore-Ball, Narang and Vergroesen 1991;Thomsen et al 1992). Cement leakage and migration of the plug were observed frequently and osteolysis of the bone around the plug was seen in 5% of firmly fixed prostheses by five The Thackray polyethylene cement plug.…”
supporting
confidence: 77%
“…We have shown that the Thackray polyethylene plug (Fig. 1) has a failure rate of at least 25%, and this has been confirmed by others (Bakker et al 1988;Northmore-Ball, Narang and Vergroesen 1991;Thomsen et al 1992). Cement leakage and migration of the plug were observed frequently and osteolysis of the bone around the plug was seen in 5% of firmly fixed prostheses by five The Thackray polyethylene cement plug.…”
supporting
confidence: 77%
“…Thomsen compared three polyethylene plug designs [16], and Bulstra tested a biodegradable polylactic model with a polyethylene plug [3].…”
Section: Introductionmentioning
confidence: 99%
“…Various experimental studies have been published on the efficacy of intramedullary plugs (Oh et al 1978, Lee and Ling 1981, Beim et al 1989, Maltry et al 1995, Prendergast et al 1999, Yee et al 1999, Heisel et al 2003. Pressure measurements, testing of shear stresses, and examination of the effects of back bleeding have been done; a few comparative studies have analyzed the clinical outcome and performance of cement restrictors (Thomsen et al 1992, Bulstra et al 1996, Visser et al 2002.…”
Section: Discussionmentioning
confidence: 99%
“…■ For adequate cement interdigitation, the use of a distal intramedullary cement restrictor (plug) is essential in order to obtain high cement pressures (Markolf and Amstutz 1976, Bannister and Miles 1988, Bean et al 1988. Plug performance should be consistent and reliable, but comparative clinical studies have shown high variability between different designs and materials (Thomsen et al 1992, Bulstra et al 1996, Visser et al 2002. Even wellcontrolled biomechanical tests have confirmed that there is a high variability in plug performance with regard to stability and occlusion of the intramedullary cavity (Prendergast et al 1999, Danter et al 2000, Heisel et al 2003.…”
mentioning
confidence: 99%