2022
DOI: 10.1016/j.mechmachtheory.2021.104568
|View full text |Cite
|
Sign up to set email alerts
|

intraOcular RoBotic Interventional System (iORBIS): Mechanical design for distally-actuated instrument insertion and automatic tool change

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 38 publications
0
5
0
Order By: Relevance
“…In this study, we applied the iORBIS robotic manipulator 18 to perform simulated SRI automatically on the retinal phantom. Various surgical parameters, including retinal curvature, insertion angle, and injection speed, were evaluated to understand their influence on bleb formation.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In this study, we applied the iORBIS robotic manipulator 18 to perform simulated SRI automatically on the retinal phantom. Various surgical parameters, including retinal curvature, insertion angle, and injection speed, were evaluated to understand their influence on bleb formation.…”
Section: Discussionmentioning
confidence: 99%
“…It is worth mentioning that image‐based guidance was necessary as the PolyTip cannula was soft and could be slightly bent during insertion. In addition, the backlash errors were assessed to determine the positioning error of the iORBIS manipulator, which reached a maximum of 3 mm 18 . Therefore, it was very challenging to perform automated insertion only based on the predetermined distance between the cannula and the target injection position.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…It can be improved by the kinematic calibration. The kinematic calibration is an effective way to improve the motion control accuracy of the RCM manipulator, thereby facilitating the RCM manipulator to better meet the clinical demands for high accuracy 18,56,57 The presence of nonlinear factors.…”
Section: Discussionmentioning
confidence: 99%
“…The kinematic calibration is an effective way to improve the motion control accuracy of the RCM manipulator, thereby facilitating the RCM manipulator to better meet the clinical demands for high accuracy. 18,56,57 (2) The presence of nonlinear factors. They play a crucial role in a control system as complex as RCM manipulators.…”
Section: Conflict Of Interest Statementmentioning
confidence: 99%