2006
DOI: 10.1016/j.transproceed.2005.12.086
|View full text |Cite
|
Sign up to set email alerts
|

Intraoperative Blood Flow Measurements and Liver Allograft Function: Preliminary Results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…Interestingly, we observed a marked similarity between the predictive ability of PDRr60 and PDR1 values. PDRr60 values were slightly higher than PDR1 values, probably because of the hyperperfusion status existing at this time 8, 12, 13…”
Section: Discussionmentioning
confidence: 78%
“…Interestingly, we observed a marked similarity between the predictive ability of PDRr60 and PDR1 values. PDRr60 values were slightly higher than PDR1 values, probably because of the hyperperfusion status existing at this time 8, 12, 13…”
Section: Discussionmentioning
confidence: 78%
“…If a flow meter is unavailable, a Doppler ultrasound of the portal vein can be performed and the waveform analyzed intraoperatively, although this is not as precise as a flow meter. We believe that there are enough data to support the practice that measured portal flows should be obtained and we do so routinely (1,2). If there is significant improvement in portal flow, then the LRV can be ligated at its confluence with the IVC with either a stapler or a ligature.…”
Section: Discussionmentioning
confidence: 96%
“…In orthotopic liver transplantation (LT), adequate portal venous flow is critical for graft survival and function (1–3). Multiple factors can contribute to inadequate portal venous flow.…”
Section: Introductionmentioning
confidence: 99%
“…The intraoperative measurement of the portal venous flow in pediatric patients submitted to liver transplantation can predict which of them are likely to develop portal thrombosis (8) . Additionally, results of preliminary studies suggest that, among several variables, portal flow volume seems to be a good marker for hepatic function (9) . On the other hand, schistosomal portal hypertension has been considered as an ideal model for the study of portal flow physiology (5) .…”
Section: Introductionmentioning
confidence: 99%
“…Despite the wide availability and widespread use of the method, the literature demonstrates controversial results in relation to the Doppler US reproducibility in the measurement of several dopplerfluxometric parameters, among them the flow volume, utilized in the evaluation of the portal vein (9,14) .…”
Section: Introductionmentioning
confidence: 99%