2006
DOI: 10.1016/s0377-1237(06)80157-7
|View full text |Cite
|
Sign up to set email alerts
|

Intrapartum Electronic Foetal Monitoring : Does it Lead or Mislead?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…4 Potential reasons why cardiotocography has failed to fulfill its potential include erroneous interpretation, interobserver variation, and a lack of standardized guidelines. 2,5,6 Cardiotocography has high sensitivity, limited specificity, and a 60% false-positive rate. 7,8 Consequently, a normal cardiotocography result is reassuring but abnormal cardiotocography patterns do not offer definitive evidence of fetal hypoxia and/or acidosis.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…4 Potential reasons why cardiotocography has failed to fulfill its potential include erroneous interpretation, interobserver variation, and a lack of standardized guidelines. 2,5,6 Cardiotocography has high sensitivity, limited specificity, and a 60% false-positive rate. 7,8 Consequently, a normal cardiotocography result is reassuring but abnormal cardiotocography patterns do not offer definitive evidence of fetal hypoxia and/or acidosis.…”
Section: Introductionmentioning
confidence: 99%
“…Potential reasons why cardiotocography has failed to fulfill its potential include erroneous interpretation, interobserver variation, and a lack of standardized guidelines . Cardiotocography has high sensitivity, limited specificity, and a 60% false‐positive rate .…”
Section: Introductionmentioning
confidence: 99%
“…3 A nonreassuring trace occurs in up to 50% of all recordings but only a small proportion of these fetuses are at risk of hypoxia. 4 Clinical outcome of fetal distress can be assessed by Apgar score, umbilical artery PH, neonatal encephalopathy, perinatal death and cerebral palsy which have been used in isolation or in combination.…”
mentioning
confidence: 99%
“…Fetal monitors provide satisfactory and accurate monitoring of the heartbeat of the fetus and contractions of the uterus. The pattern of the fetus’s heart beat usually reflects its health [ 2 ]. The collected pattern data may be used to determine the status of the fetus during the prenatal stage or during the birth process.…”
Section: Introductionmentioning
confidence: 99%