Invasive and non-invasive point-of-care testing and point-of-care monitoring of the hemoglobin concentration in human blood – how accurate are the data?

Abstract: In this review, scientific investigations of point-of-care testing (POCT) and point-of-care monitoring (POCM) devices are summarized with regard to the measurement accuracy of the hemoglobin concentration. As a common basis, information according to the Bland and Altman principle [bias, limits of agreement (LOA)] as well as the measurement accuracy and precision are considered, so that the comparability can be mapped. These collected data are subdivided according to the manufacturers, devices and procedures (i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 35 publications
0
5
0
Order By: Relevance
“…However, this form of overview has two major blind spots: firstly, the systematic measurement error of the reference is negated, and secondly, an evaluation of the measurement accuracy in the form of a representative zone is not provided for a range below 6 g/dL. The TLA form of representation was an attempt to close these blind spots [ 7 ]. This is based on the B and A principle that every device or process will show some systematic error.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…However, this form of overview has two major blind spots: firstly, the systematic measurement error of the reference is negated, and secondly, an evaluation of the measurement accuracy in the form of a representative zone is not provided for a range below 6 g/dL. The TLA form of representation was an attempt to close these blind spots [ 7 ]. This is based on the B and A principle that every device or process will show some systematic error.…”
Section: Discussionmentioning
confidence: 99%
“…In contrast to the error grid representation of Clark [ 16 , 39 ] we selected the TLA as representative due to the obvious advantages of this method. In particular, these take into account tHb values below 6 g/dL and the consideration of potential systematic errors regarding the measurement methods [ 7 ]. As with the error grid representation, representative zones are defined.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations