2022
DOI: 10.18618/rep.2022.4.0016
|View full text |Cite
|
Sign up to set email alerts
|

Inversor Integrado Zeta para Aplicações em Sistemas Autonômos Monofásicos de Geração de Energia

Abstract: Resumo -Este trabalho apresenta uma nova topologia integrada de inversor monofásico para aplicações autônomas em sistemas de geração de energia. A topologia proposta, nomeada como Inversor Integrado Zeta Monofásico (I2ZM), é projetada para fornecer uma tensão senoidal, regulada e com baixa distorção harmônica para cargas locais a partir de fontes de tensão CC, em um sistema de geração autônomo. O I2ZM é construído a partir da integração de conversores CC-CC Zeta, sendo este projetado para operar no modo de con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…The Zeta-based integrated inverter was also presented in [17], operating as a standalone sinusoidal voltage source for autonomous GD/battery systems. However, the operation in the DCM can be represented by less complex and challenging mathematical models from the point of view of the output voltage controller.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Zeta-based integrated inverter was also presented in [17], operating as a standalone sinusoidal voltage source for autonomous GD/battery systems. However, the operation in the DCM can be represented by less complex and challenging mathematical models from the point of view of the output voltage controller.…”
Section: Introductionmentioning
confidence: 99%
“…However, using the converter in the CCM for the same power level reduces the RMS value of the currents in the power switches and diodes, which indicates a more efficient operation once the elevated RMS currents are related to conduction losses. Nonetheless, this article proposes the SP-IZI converter operating in the CCM, making it more efficient than previous proposals [15][16][17] and able to operate as a sinusoidal voltage source for local loads. At the same time, the proposed controller overcomes the difficulties in controlling the output voltage without the need to measure the output inductor current.…”
Section: Introductionmentioning
confidence: 99%