2018
DOI: 10.1002/app.47147
|View full text |Cite
|
Sign up to set email alerts
|

Investigating the crosslinking effects on surface characteristics of vinyltrimethoxysilane‐grafted moisture‐cured low‐density polyethylene/ethylene vinyl acetate blend

Abstract: In this article, the adhesion attributed characteristics of vinyltrimethoxysilane‐grafted moisture‐cured low‐density polyethylene/ethylene vinyl acetate (VTMS‐grafted LDPE/EVA) blend have been investigated before, during, and after crosslinking process. Characterization of the changes due to the moisture‐induced crosslinking has been carried out as a function of vapor exposure (crosslinking) duration. Fourier transform infrared (FTIR) spectroscopy was used for identification of compounds based on functional gr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 70 publications
(79 reference statements)
0
3
0
Order By: Relevance
“…On the other hand, it is easy to detect the LDPE coat over the f‐SiNP by the absorption bands at 2850 and 2915 cm −1 appearing in all the LDPE/f‐SiNP spectra of Figure 3D, F, and H. Since these two frequency bands represent the symmetric and asymmetric stretching vibration of –CH 2 in LDPE, 38 it is proved that the LDPE coating has surrounded the surface of f‐SiNP.…”
Section: Resultsmentioning
confidence: 93%
“…On the other hand, it is easy to detect the LDPE coat over the f‐SiNP by the absorption bands at 2850 and 2915 cm −1 appearing in all the LDPE/f‐SiNP spectra of Figure 3D, F, and H. Since these two frequency bands represent the symmetric and asymmetric stretching vibration of –CH 2 in LDPE, 38 it is proved that the LDPE coating has surrounded the surface of f‐SiNP.…”
Section: Resultsmentioning
confidence: 93%
“…Low‐density PE was later replaced by cross‐linked PE due to its improved properties. Cross‐linked PE exhibits better resistance to water treeing, better environmental stress cracking resistance, resistance to higher temperatures, and especially greater dimensional stability, all improvements over uncross‐linked PE 14–20 . However, crosslinking of thermoplastics alters the materials to those that no longer melt and lose melt processability or renewability.…”
Section: Introductionmentioning
confidence: 99%
“…Crosslinked PE exhibits better resistance to water treeing, better environmental stress cracking resistance, resistance to higher temperatures, and especially greater dimensional stability, all improvements over uncross-linked PE. [14][15][16][17][18][19][20] However, crosslinking of thermoplastics alters the materials to those that no longer melt and lose melt processability or renewability. Furthermore, improving the dielectric properties and dimensional stability of polymers by introducing inorganic fillers is also a commonly used strategy, considering their low CTE and abundance.…”
mentioning
confidence: 99%