2017
DOI: 10.1016/j.electacta.2017.03.162
|View full text |Cite
|
Sign up to set email alerts
|

Investigating the effects of gas diffusion layer substrate thickness on polymer electrolyte membrane fuel cell performance via synchrotron X-ray radiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
36
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 55 publications
(38 citation statements)
references
References 70 publications
2
36
0
Order By: Relevance
“…MPL). Equation (3.5) will then lead to the calculation of a negative value [24,118,119]. While this observation is graphically indicated as negative water thickness or negative saturation in this study, the change in optical depth is in fact a physically meaningful and potentially useful indication of material displacement.…”
Section: Comment On Materials Movementmentioning
confidence: 83%
See 1 more Smart Citation
“…MPL). Equation (3.5) will then lead to the calculation of a negative value [24,118,119]. While this observation is graphically indicated as negative water thickness or negative saturation in this study, the change in optical depth is in fact a physically meaningful and potentially useful indication of material displacement.…”
Section: Comment On Materials Movementmentioning
confidence: 83%
“…While this observation is graphically indicated as negative water thickness or negative saturation in this study, the change in optical depth is in fact a physically meaningful and potentially useful indication of material displacement. It is possible to identify and diagnose delamination events and membrane swelling or shrinkage events [118,119] by calculating the positive or negative change in optical depth relative to the reference image. The effects of material movement on liquid water quantification were confined to the pixels near material interfaces.…”
Section: Comment On Materials Movementmentioning
confidence: 99%
“…A description of the model and parameter fitting procedure are provided in our previous studies. 13,35,36,47 In-operando measurement of liquid water.-Synchrotron imaging.-Radiographs of the operating fuel cell were acquired at the Biomedical Imaging Therapy Bending Magnet beamline (05B1-1) of the Canadian Light Source Inc. (CLS) (Saskatoon, Canada). 48 The energy level of the monochromatic X-ray beam was set to 24 keV, and a pixel resolution of 6.5 μm was achieved with a temporal resolution of 3 seconds per frame.…”
Section: Experimental Methodologymentioning
confidence: 99%
“…The voltages at 1000 mA/ cm 2 for 29-WUT and 29 BC were 0.73 and 0.66 V, respectively. 6 As can be seen in Figure 4 and Table 1, the R a at 1000 mA/cm 2 of 2 MEAs with 29 BC and 29-WUT were about 2.70 and 2.67 mΩ, and the R a at 1600 mA/cm 2 were about 2.58 and 2.57 mΩ. To clarify the reasons for this phenomenon, a series of measurements were thus conducted.…”
Section: The Performance Of Measmentioning
confidence: 91%
“…It is sandwiched between flow field and catalyst layer (CL), and its functions are to supply reactant gases to the electrodes, to remove product water, and to provide good electrical and thermal contact. The designs of GDL, such as thickness, 6,7 pore size, 8,9 porosity, 10,11 hydrophobicity, 12,13 hydrophilicity, 14 compression ratio, [15][16][17] and the role of cracks in MPL structure [18][19][20] have been evolved significantly during recent years with the key aim of improving their performance for delivering their role.…”
Section: Introductionmentioning
confidence: 99%