2020
DOI: 10.1002/bio.3962
|View full text |Cite
|
Sign up to set email alerts
|

Investigating the interaction of mitoxantrone with anionic surfactants by spectrofluorimetry and its application for the feasible analysis of pharmaceutical preparation and biological fluids

Abstract: The behaviour of mitoxantrone (MTX), an anthracenedione antineoplastic agent, in different types of organized medium was explored using molecular spectrofluorometry. The original fluorescence and quantum yield of MTX were augmented by about five‐fold in the aqueous buffered solution (Britton–Robinson, pH 3.0) by the addition of sodium dodecyl sulfate. Enhancement in the fluorescence intensity did not come from the boost in the ultraviolet (UV) light absorbance of the drug in the presence of micelles but due to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 39 publications
0
12
0
Order By: Relevance
“…Many dispersing solvents were investigated, including ethyl alcohol, methyl alcohol, 2-propanol, acetone, dioxane, and distilled water (ESI, 6.1 † ). For the designed spectroscopic approach, the greatest fluorescence quenching values were gained when distilled water (the best green solvent 38 ) was the dispersion medium. The low response obtained with organic solvents in the present study may be due to the destructive effect of these solvents on the formed complex.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Many dispersing solvents were investigated, including ethyl alcohol, methyl alcohol, 2-propanol, acetone, dioxane, and distilled water (ESI, 6.1 † ). For the designed spectroscopic approach, the greatest fluorescence quenching values were gained when distilled water (the best green solvent 38 ) was the dispersion medium. The low response obtained with organic solvents in the present study may be due to the destructive effect of these solvents on the formed complex.…”
Section: Resultsmentioning
confidence: 99%
“…The recommended spectroscopic methodology was employed to assess MTX in its pharmaceutical prescription form (Santrone® vial). The reported spectrofluorimetric technique 38 was also used to examine the same dosage form. Using two statistical tests ( t -test and F -test), the percentage recovery values of the reported spectrophotometric technique were statistically rated against those obtained from the developed system.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations