2010
DOI: 10.1002/sia.3379
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of 1‐butyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide under Binx+ cluster ion bombardment

Abstract: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to study 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide under Bi-ion and Bi-cluster-ion (Bi 2 -7 + , Bi 3,5,7 ++ ) bombardment in positive and negative polarity. Peak pattern as well as practical experiences with the bismuth cluster LMIG is discussed. Mass spectra with the best mass resolution were obtained using Bi 3 ++ or Bi 5 ++ as primary ion source. The secondary ion yield of high molecular ion is enhanced up to two orders o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
2
0

Year Published

2010
2010
2013
2013

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 23 publications
1
2
0
Order By: Relevance
“…The primary ion current was directly measured using a Faraday cup detector located on a grounded sample holder (for Bi 1 + , Bi 2 + , Bi 3 + and Bi 3 2+ ) or was determined indirectly via extrapolation of target current measurements with adequate variation of pulse width at a given cycle time, usually 20 µs (for Bi 4 + , Bi 5 + , Bi 6 + , Bi 7 + and Bi 5 2+ ). [20,21] The difference between the measured ion currents was at maximum ±5% which is in good agreement to previously published data. [20,22,23] and a primary ion energy of 25 keV for single charged ion clusters and 50 keV for double charged ion clusters.…”
Section: Introductionsupporting
confidence: 89%
See 1 more Smart Citation
“…The primary ion current was directly measured using a Faraday cup detector located on a grounded sample holder (for Bi 1 + , Bi 2 + , Bi 3 + and Bi 3 2+ ) or was determined indirectly via extrapolation of target current measurements with adequate variation of pulse width at a given cycle time, usually 20 µs (for Bi 4 + , Bi 5 + , Bi 6 + , Bi 7 + and Bi 5 2+ ). [20,21] The difference between the measured ion currents was at maximum ±5% which is in good agreement to previously published data. [20,22,23] and a primary ion energy of 25 keV for single charged ion clusters and 50 keV for double charged ion clusters.…”
Section: Introductionsupporting
confidence: 89%
“…The vacuum in the analysis chamber was kept in the range of 10 −8 mbar and 10 −9 mbar during all measurements. The mass scale was calibrated using a number of well defined and easily assignable secondary ions; [21] …”
Section: Introductionmentioning
confidence: 99%
“…The occurrence of such clusters is not restricted to ESI and is observed also with other ionisation methods. [31][32][33] Also, this type of cluster ion is not unique to the ILs, it is in fact commonly observed for ionic, salt-like species and there have been earlier studies by this group on non-IL cluster ions of this type. [34][35][36] In tandem mass spectrometry experiments a cluster ion of choice is separated from others and allowed to dissociate.…”
Section: Introductionmentioning
confidence: 96%