2013
DOI: 10.1109/tdei.2013.6451376
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of aging degradation status of insulating elements in oil-immersed transformer and its diagnostic method based on field measurement data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
21
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(22 citation statements)
references
References 7 publications
0
21
0
1
Order By: Relevance
“…Their reliability is significant for the safety and stability of power grids [1]. It is well known that dissolved CO and CO 2 [2,3], furans [4,5] and dielectric properties of oil [6,7] can be used for the aging evaluation of an operating transformer [8]. Under the long-term operation, mineral oil will react with dissolved oxygen to form carboxylic acids of varying molecular weight and then dissolve in transformer oil [9].…”
Section: Introductionmentioning
confidence: 99%
“…Their reliability is significant for the safety and stability of power grids [1]. It is well known that dissolved CO and CO 2 [2,3], furans [4,5] and dielectric properties of oil [6,7] can be used for the aging evaluation of an operating transformer [8]. Under the long-term operation, mineral oil will react with dissolved oxygen to form carboxylic acids of varying molecular weight and then dissolve in transformer oil [9].…”
Section: Introductionmentioning
confidence: 99%
“…The permissible concentrations of furfural in oil is 1.5 mg/L at caution and 15 mg/L at danger level respectively. 6 The proposed method in this paper has ability to alarm when abnormal ageing occurs in transformer, and meet the basic requirements of engineering application. …”
Section: Resultsmentioning
confidence: 99%
“…Therefore, the evaluation of insulation ageing condition is usually achieved by detecting the content of furfural in oil. [3][4][5][6] High-performance liquid chromatography (HPLC), colorimetric method and ultraviolet (UV) spectrophotometry were traditionally used to detect furfural content in oil. However, HPLC requires professionals to perform complex operations in lab, and has elution difficulty and extra column effect.…”
Section: Introductionmentioning
confidence: 99%
“…The safety and stability of such transformers are both important and necessary in operating power systems [3]. Oil-paper insulation is an important form of power transformer insulation system; the remaining life of the transformer largely depends on the insulation status of oil-paper which is affected by thermal, mechanical, partial discharge and other aging factors in the long-running process [4][5][6]. Therefore, using an accurate assessment tool to evaluate the condition of oil-paper insulation has become a popular research topic.…”
Section: Introductionmentioning