2016
DOI: 10.1016/j.net.2016.08.007
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 18 publications
0
7
0
Order By: Relevance
“…In these cases, the conjugate heat transfer should be considered to better analyse the thermal performance of two-phase processes in power plants. Such a method is vital to satisfy the demand for high cooling and heat rates in power plants (Wu et al, 2010;Minocha et al, 2016;Noori Rahim Abadi et al, 2018c). Nie et al (2017) studied the conjugate condensation of highpressure steam inside a tube and atmospheric pool boiling outside a tube experimentally.…”
Section: Conjugate Heat-transfer Phenomenamentioning
confidence: 99%
“…In these cases, the conjugate heat transfer should be considered to better analyse the thermal performance of two-phase processes in power plants. Such a method is vital to satisfy the demand for high cooling and heat rates in power plants (Wu et al, 2010;Minocha et al, 2016;Noori Rahim Abadi et al, 2018c). Nie et al (2017) studied the conjugate condensation of highpressure steam inside a tube and atmospheric pool boiling outside a tube experimentally.…”
Section: Conjugate Heat-transfer Phenomenamentioning
confidence: 99%
“…Sun et al 2 proposed that using bayonet cooling thimble scan improve the performance of residual system in a 10-MW MSR, and they performed a series of experimental and numerical works to verify the feasibility of their PRHRS design. [3][4][5] Chen et al 6 proposed a full-scaled PRHRS design with six cooling thimbles which have been used in the system for a 2-MW MSR. The transient behaviors of natural circulation in system during start-up process are researched.…”
Section: Introductionmentioning
confidence: 99%
“…Sun Lu et al conducted research on the conceptual design of a PRHRS for a 10 MW MSRE. Then based on this conceptual design, a series of experimental and numerical studies have been carried out . Wang et at proposed a new conceptual design of PRHRS by using heat pipes and conducted some analysis on the heat pipes performance in the system.…”
Section: Introductionmentioning
confidence: 99%
“…Then based on this conceptual design, a series of experimental and numerical studies have been carried out. [14][15][16] Wang et at 17 proposed a new conceptual design of PRHRS by using heat pipes and conducted some analysis on the heat pipes performance in the system. However, these PRHRS designs proposed for the MSR of Generation IV are all in the stage of theoretical design.…”
Section: Introductionmentioning
confidence: 99%