Medical Imaging 2005: Physics of Medical Imaging 2005
DOI: 10.1117/12.596089
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of cone-beam acquisitions implemented using a novel dedicated mammotomography system with unique arbitrary orbit capability (Honorable Mention Poster Award)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
27
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(27 citation statements)
references
References 0 publications
0
27
0
Order By: Relevance
“…As has been demonstrated by us, this also leads to more nearly complete sampling throughout a larger object FOV. 8,26,27,41,44 In both cases, due to the symmetrical nature of the orbits about the 3D center of rotation (COR), the dose deposition in the volume is approximately radially symmetric. This is easily seen in the coronal Monte Carlo results [ Fig.…”
Section: Discussionmentioning
confidence: 99%
“…As has been demonstrated by us, this also leads to more nearly complete sampling throughout a larger object FOV. 8,26,27,41,44 In both cases, due to the symmetrical nature of the orbits about the 3D center of rotation (COR), the dose deposition in the volume is approximately radially symmetric. This is easily seen in the coronal Monte Carlo results [ Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Due to the failure to meet this condition with a wide cone-beam, reconstruction of slices for locations further away from the flat plane of the beam (which is parallel to the ground and intersects the focal point) contains significant distortion and errors. This incompleteness in circular trajectories with cone-beam acquisitions has been seen to degrade the reconstructed images, especially with the use of large cone angles (Webb et al 1987, Kudo and Saito 1990, Davis 2005, McKinley et al 2005a. Figure 5 (bottom left) illustrates the cause of the insufficient sampling in our experimental setup.…”
Section: Disk Phantom Without Acrylic Ballsmentioning
confidence: 99%
“…Various groups that have developed cone-beam dedicated breast CT tomographic scanners have also been limited to using a circular scan during image acquisition (Chen and Ning 2002, Vedula and Glick 2003, Chen et al 2005, Boone et al 2006. This limits the CT system in its ability to image deep into the breast and chest wall, and introduces insufficient sampling which has previously been shown to be eliminated by using 3D complex acquisition trajectories (Kudo and Saito 1990, Zeng et al 1994, Junhai et al 2003, McKinley et al 2005a. In this study, we describe the configuration of the dual-modality SPECT-CT system and evaluate the effects on object distortion with the CT system at different stationary tilts.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Improvement of patient positioning is necessary to optimize the inclusion of the breast tissue up to the chest wall. 8 Typically, two parameters are used for evaluating breast coverage: the visibility of anatomical points described by O'Connell et al 9 and the volume and length of the breast in the field of view below the patient table. 10 With the help of those parameters, it is also possible to evaluate breast tissue coverage for different patient positions and to accommodate other influences such as a patient's breathing.…”
Section: Introductionmentioning
confidence: 99%