Investigation of Electric and Magnetic Field in the Application of Dynamic Line Rating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2
1
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…This paper demonstrates that the electric field can exceed the limit value even if the legally defined safety distance is observed in dedicated power lines. For this purpose, the authors performed electric field measurements and numerical simulations several times in the vicinity of an active transmission line on which DLR sensors are installed [27,28]. The measurements were performed in the most critical power line span with regards to ground clearance, in planes perpendicular to the transmission line's longitudinal direction.…”
Section: General Conceptmentioning
confidence: 99%
“…This paper demonstrates that the electric field can exceed the limit value even if the legally defined safety distance is observed in dedicated power lines. For this purpose, the authors performed electric field measurements and numerical simulations several times in the vicinity of an active transmission line on which DLR sensors are installed [27,28]. The measurements were performed in the most critical power line span with regards to ground clearance, in planes perpendicular to the transmission line's longitudinal direction.…”
Section: General Conceptmentioning
confidence: 99%
“…Theoretically, the use of DLR does not violate the legally defined clearances, since the aim of this method is to always maintain the maximum allowable temperature. However, measurement and model errors or control inaccuracies may cause the temperature limits to be exceeded for a short time that need to be treated proper [2][3][4], [8].…”
Section: Fig 2 Visualization Of Sag and Clearance In Case Of A Simpli...mentioning
confidence: 99%
“…The maximum allowable conductor temperature is 40 °C and the static line rating is 530 A for the summer period. Due to legal requirements, most of the spans need to fulfill 7 m as a clearance criterium, but there are some exceptions where 5.5 m is the safety distance [4][5][6][7].…”
Section: Risk Factor Analysis Of Ohl Sagmentioning
confidence: 99%