Investigation of Induced Charge Mechanism on a Rod Electrode

Abstract: Rod electrodes based on an electrostatic induction mechanism are widely used in various industrial applications, but the analytic solution of an induced charge mechanism on a metal rod electrode has not yet been systematically established. In this paper, the theoretical model of the induced charge on a rod electrode is obtained through the method of images. Then, the properties of the rod electrode under the action of the point charge are studied, including the induced charge density distribution on the rod el… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…One electrode is the noise collection terminal, which mainly collects noise signals in the detection environment, and the other electrode is the signal collection terminal, which mainly collects noise-containing microelectric signals. According to the positive correlation between the induction signal and the size of the electrode [ 6 ], it can be assumed that the induction signal obtained by the noise-collecting electrode is much smaller than the induction signal measured by the measuring electrode and that noise is the main component. The noise-collecting electrode is much smaller than the measuring electrode, having a length of 20–30 mm and a diameter of 1–2 mm.…”
Section: Signal Acquisitionmentioning
confidence: 99%
See 2 more Smart Citations
“…One electrode is the noise collection terminal, which mainly collects noise signals in the detection environment, and the other electrode is the signal collection terminal, which mainly collects noise-containing microelectric signals. According to the positive correlation between the induction signal and the size of the electrode [ 6 ], it can be assumed that the induction signal obtained by the noise-collecting electrode is much smaller than the induction signal measured by the measuring electrode and that noise is the main component. The noise-collecting electrode is much smaller than the measuring electrode, having a length of 20–30 mm and a diameter of 1–2 mm.…”
Section: Signal Acquisitionmentioning
confidence: 99%
“…The relative concentration and mass flow rate are then obtained from the root mean square value output by two ring electrodes. The present authors [ 6 ] have conducted research on the theory of mine dust belt motors, charging modes, charging measurement models, and measuring devices and have identified nonlinear characteristics in the dust electrostatic signal that reflect the multiscale information contained in the signal. Because the measurement environment of the detection device is complex and changeable, the measured dust electrostatic signal always contains noise.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…is paper adopts the method of constructing an LSTM network and fully connected layer to improve the model prediction accuracy. Generally speaking, the deeper the deep learning network, the better the expression effect of the neural network [40][41][42].…”
Section: Application Of the Lstm Modelmentioning