2013
DOI: 10.1107/s0108768113002954
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of non-corrin cobalt(II)-containing sites in protein structures of the Protein Data Bank

Abstract: Protein X-ray structures with non-corrin cobalt(II)-containing sites, either natural or substituting another native ion, were downloaded from the Protein Data Bank and explored to (i) describe which amino acids are involved in their first ligand shells and (ii) analyze cobalt(II)-donor bond lengths in comparison with previously reported target distances, CSD data and EXAFS data. The set of amino acids involved in Co II binding is similar to that observed for catalytic Zn II sites, i.e. with a large fraction of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 33 publications
0
7
0
Order By: Relevance
“…Using the “Low resolution adjustment” option will not change the calculated parameters for each site, but will change the thresholds used to distinguish the outlier-borderline-acceptable ranges as indicated by red-amber-green background colors. This option will only affect structures with a resolution worse than 2 Å 10,16 . ▲ CRITICAL STEP The authors suggest that less experienced users not use this option. As metal coordination chemistry itself obviously does not depend on the resolution of structural data, the consideration of resolution in the evaluation of metal binding site quality is questionable in itself.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Using the “Low resolution adjustment” option will not change the calculated parameters for each site, but will change the thresholds used to distinguish the outlier-borderline-acceptable ranges as indicated by red-amber-green background colors. This option will only affect structures with a resolution worse than 2 Å 10,16 . ▲ CRITICAL STEP The authors suggest that less experienced users not use this option. As metal coordination chemistry itself obviously does not depend on the resolution of structural data, the consideration of resolution in the evaluation of metal binding site quality is questionable in itself.…”
Section: Methodsmentioning
confidence: 99%
“…Using the “Low resolution adjustment” option will not change the calculated parameters for each site, but will change the thresholds used to distinguish the outlier-borderline-acceptable ranges as indicated by red-amber-green background colors. This option will only affect structures with a resolution worse than 2 Å 10,16 .…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations