Investigation of optimal scanning protocol for X-ray computed tomography polymer gel dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
2
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 26 publications
2
2
0
Order By: Relevance
“…The 50–50 MANOVA analysis of parameter samples (Table 3) showed that most of the variation in CT value was explained by the chemical composition of the samples (96.8%). As expected (Allen and Leymaster 1985; Qamhiyeh 2007; Sellakumar and others 2007), the most important scanner parameter was tube voltage, which explained 2% of the variance in CT values of the parameter samples. Also, Figure 2 shows that CT values of different tissue depended on the tube voltage.…”
Section: Resultssupporting
confidence: 76%
See 2 more Smart Citations
“…The 50–50 MANOVA analysis of parameter samples (Table 3) showed that most of the variation in CT value was explained by the chemical composition of the samples (96.8%). As expected (Allen and Leymaster 1985; Qamhiyeh 2007; Sellakumar and others 2007), the most important scanner parameter was tube voltage, which explained 2% of the variance in CT values of the parameter samples. Also, Figure 2 shows that CT values of different tissue depended on the tube voltage.…”
Section: Resultssupporting
confidence: 76%
“…Literature discussing CT scan protocols focuses on minimizing the image noise, but low noise and high separation are 2 different phenomena. A low tube voltage (80 kV) is associated with a high standard deviation in the CT values of the image (Sellakumar and others 2007), as confirmed by our study. Allen and Leymaster (1985) found a 37% reduction in noise by increasing the voltage from 96 to 125 kV; however, CT image noise is mainly due to random variations in detected x‐ray intensity (Jørgensen 2002; Goldman 2007a), and is thus probably a more significant problem in qualitative than in quantitative CT. Also, the samples in this study were small, reducing the need for high energy photons.…”
supporting
confidence: 85%
See 1 more Smart Citation
“…Scanning parameters can be optimized [ 366 , 367 ], and it is concluded that minimizing phantom size and maximizing tube voltage are recommended. In the light of scanning parameter optimization, a conventional X-ray computed tomography scanner was modeled by use of a Monte Carlo simulation [ 368 ]. An additional strategy to increase the SNR in the X-ray derived dose maps is the use of post-processing image filtering techniques [ 369 , 370 , 371 ].…”
Section: Readout Systemsmentioning
confidence: 99%