Investigation of photoplethysmographs from the anterior fontanelle of neonates

Abstract: This is the accepted version of the paper.This version of the publication may differ from the final published version. Abstract. Photoplethysmography (PPG) signals have been investigated at a new anatomical site, the anterior fontanelle (ANTF), on the hypothesis that blood supply at this location is preferentially preserved during cases of poor peripheral circulation which might cause the commercial pulse oximeters to fail to estimate accurately arterial blood oxygen saturation (SpO2). Two custom built reflect… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…While many studies have been previously conducted into the placement of PPG sensors for pulse oximetry [5,10,11,12,13,14,15,16,17], few studies have been conducted for a suitable location to collect heart rate, SpO 2 , and respiration. Kramer et al [10] developed a new pulse oximeter for use at non-traditional anatomical locations for the measurement of heart rate, SpO 2 , and respiration.…”
Section: Introductionmentioning
confidence: 99%
“…While many studies have been previously conducted into the placement of PPG sensors for pulse oximetry [5,10,11,12,13,14,15,16,17], few studies have been conducted for a suitable location to collect heart rate, SpO 2 , and respiration. Kramer et al [10] developed a new pulse oximeter for use at non-traditional anatomical locations for the measurement of heart rate, SpO 2 , and respiration.…”
Section: Introductionmentioning
confidence: 99%
“…The cylindrical fontanelle model (diameter: 120 mm, height: 95 mm) has a diamond-shaped opening (3 × 4 cm 2 ) to mimic the opening of anterior fontanelle of infants, and encloses a balloon (Elite, Durex ® , Parsippany, NJ, USA) connected to a computer-controlled pressure pump (OB1, Elveflow, Paris, France) (Figure 1C,D). The typical opening area of the anterior fontanelle in normal infants is known to be 2 × 3 cm 2 [44,45], but considering that the opening area of the bulging fontanelle for ill infants is usually larger than that of healthy infants [46][47][48][49], we have designed the model to have a slightly larger opening (Figure 1C). Pressures from 0 mbar to 220 mbar were applied to the balloon for testing the operational pressure range of the developed fontanelle model.…”
Section: Artificial Fontanelle Modelmentioning
confidence: 99%
“…Work previously carried out on designing and constructing flexible reflectance PPG sensors with unusual geometry [11,12] was adapted to produce a sensor fit for the purpose of placing in the human trachea. A custom, flexible, printed circuit board (PCB) and silicone rubber covering were modelled in SolidWorks (Dassault Systèmes, Vélizy-Villacoublay, France).…”
Section: The Endotracheal Sensormentioning
confidence: 99%