2018
DOI: 10.1016/j.ijmultiphaseflow.2018.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of surface structures in two phase wavy pipe flow by utilizing X-ray tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…The three-dimensionality of the wavefield (using the same two-phase flow loop) has previously been investigated by Strand (1993) and Smith et al. (2018). Strand (1993) used conductance wave probes at different cross-wise planes of the pipe and found that for the flow rates under investigation in the present work, the normalized cross-correlation between the centreline and off-axis surface elevation exceeded 0.85 everywhere in the pipe.…”
Section: Methodsmentioning
confidence: 94%
See 1 more Smart Citation
“…The three-dimensionality of the wavefield (using the same two-phase flow loop) has previously been investigated by Strand (1993) and Smith et al. (2018). Strand (1993) used conductance wave probes at different cross-wise planes of the pipe and found that for the flow rates under investigation in the present work, the normalized cross-correlation between the centreline and off-axis surface elevation exceeded 0.85 everywhere in the pipe.…”
Section: Methodsmentioning
confidence: 94%
“…Smith et al. (2018) used X-ray tomography and found that the dominant wave components were well-described as two-dimensional for the flow rates of interest. Near the pipe walls the waves were observed to have a crescent shape, and slightly larger wave amplitudes were observed compared with the pipe centreline.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, thresholding of the image, although useful for analyzing the dissolution patterns, leads inevitably to the information loss, as partially dissolved region are either interpreted as fully dissolved or as undissolved. In order to measure the aperture variation in the experimental images, a calibration between the thickness profile of the plaster sample and the intensity profile of the photos is performed by an X-ray Thickness Gauging REX-CELL 4X from Flow Capture [43][44][45].…”
Section: Statistical Properties Of the Dissolution Patternsmentioning
confidence: 99%