Investigation of the accuracy of VFD analog output data and the energy performance of different voltage controls in a VFD-motor-belt-fan system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 7 publications
0
2
0
1
Order By: Relevance
“…The VFD for large-sized motors can provide consistent VFD output power, which has a stable value by the filter inside the VFD. Figure 20 compares the motor power input read from a VFD and the motor power input measured by a power analyzer for a 5.6 kW (7.5 HP) motor [39]. It reveals that the VFD output power measured by the VFD is different from the actual VFD output power but has a consistent correlation with actual VFD output power.…”
Section: Discussion On Alternative Power Measurementmentioning
confidence: 99%
“…The VFD for large-sized motors can provide consistent VFD output power, which has a stable value by the filter inside the VFD. Figure 20 compares the motor power input read from a VFD and the motor power input measured by a power analyzer for a 5.6 kW (7.5 HP) motor [39]. It reveals that the VFD output power measured by the VFD is different from the actual VFD output power but has a consistent correlation with actual VFD output power.…”
Section: Discussion On Alternative Power Measurementmentioning
confidence: 99%
“…VFD memantau berbagai data operasional motor, termasuk frekuensi, arus, tegangan, dan daya. Frekuensi dan arus yang dihasilkan oleh VFD memberikan nilai yang sangat akurat sesuai dengan nilai sebenarnya, sedangkan tegangan dan daya memiliki hubungan konsisten dengan nilai aktual tetapi tidak dapat memberikan nilai yang akurat secara langsung [13].…”
Section: Penelitian Relevanunclassified
“…However, most of the existing studies have mainly conducted studies related to the energy efficiency of HVAC systems based on analysis in static conditions. These results are applicable only in the design stage, and in the actual operation stage, various factors such as changes in indoor and outdoor environmental conditions and system performance degradation affect the energy efficiency of HVAC systems [18], [19]. Therefore, for the energy-efficient operation of the HVAC system in a pig house, the role of dynamic simulation that can present a control strategy responding to changes in environmental conditions and system performance is required.…”
Section: Introductionmentioning
confidence: 99%