Investigation of the liquid density using Gamma scattering technique

Abstract: In this work, a gamma scattering technique using 137Cs (5mCi) source with the NaI(Tl) detector is arranged to record the scattered photon beam at scattering angle of 1200 for investigating the liquid density. We used standard liquid such as water, H2SO4, HCl, glycerol, HNO3, ethanol and A92 petrol to fit the single scattering peak, multiple scattering, and total counts versus standard liquid densities. The interpolating of the single scattering peak, multiple scattering, and total counts of the testing sample … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…Existing studies illustrate that the nonoptimal molar ratios of water in MIL‐101(Cr) syntheses affect the yield and porosity of the resulting HF‐MIL‐101(Cr) samples. [ 11,36,37 ] More importantly, the purification processes conducted may be inadequate in removing residual H 2 BDC, solvents, and side products within and around the pores of HF‐MIL‐101(Cr). [ 11,19,20 ]…”
Section: Variations In Activation Procedures For Hf‐based Mil‐101(cr)...mentioning
confidence: 99%
See 1 more Smart Citation
“…Existing studies illustrate that the nonoptimal molar ratios of water in MIL‐101(Cr) syntheses affect the yield and porosity of the resulting HF‐MIL‐101(Cr) samples. [ 11,36,37 ] More importantly, the purification processes conducted may be inadequate in removing residual H 2 BDC, solvents, and side products within and around the pores of HF‐MIL‐101(Cr). [ 11,19,20 ]…”
Section: Variations In Activation Procedures For Hf‐based Mil‐101(cr)...mentioning
confidence: 99%
“…Existing studies illustrate that the nonoptimal molar ratios of water in MIL-101(Cr) syntheses affect the yield and porosity of the resulting HF-MIL-101(Cr) samples. [11,36,37] More importantly, the purification processes conducted may be inadequate in removing residual H 2 BDC, solvents, and side products within and around the pores of HF-MIL-101(Cr). [11,19,20] Purification or activation processes for HF-MIL-101(Cr) samples include washing with additional solvents (heated or at room temperature) such as N,N-dimethylformamide (DMF), ethanol or methanol, and ammonium fluoride (NH 4 F) solutions.…”
Section: Variations In Activation Procedures For Hf-based Mil-101(cr)...mentioning
confidence: 99%