2021
DOI: 10.1016/j.ejmp.2021.06.014
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the magnetic susceptibility properties of fresh and fixed mouse heart, liver, skeletal muscle and brain tissue

Abstract: Several magnetic resonance imaging (MRI) techniques exploit the difference in magnetic susceptibilities between tissues, but systematic measurements of tissue susceptibility are lacking. Furthermore, there is the question as to whether chemical fixation that is used for ex vivo MRI studies, affects the magnetic properties of the tissue. Here, we determined the magnetic susceptibility and water content of fresh and chemically fixed mouse tissue. Methods: Mass susceptibility of brain, heart, liver and skeletal m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 76 publications
0
5
0
Order By: Relevance
“…To compare the magnetic susceptibilities of MagR to the known volume magnetic susceptibilities of typical tissues ( Klohs & Hirt, 2021 ), we converted mass magnetic susceptibilities in CGS units of MagR to volume magnetic susceptibilities ( Figure 5C , D). The volume magnetic susceptibilities of robin MagR and pigeon MagR were –1.4204×10 -6 and –1.2808×10 -6 , respectively, at 300 K, which are more paramagnetic than those of heart and brain tissues (–1.932×10 -5 and –6.928×10 -6 , respectively).…”
Section: Resultsmentioning
confidence: 99%
“…To compare the magnetic susceptibilities of MagR to the known volume magnetic susceptibilities of typical tissues ( Klohs & Hirt, 2021 ), we converted mass magnetic susceptibilities in CGS units of MagR to volume magnetic susceptibilities ( Figure 5C , D). The volume magnetic susceptibilities of robin MagR and pigeon MagR were –1.4204×10 -6 and –1.2808×10 -6 , respectively, at 300 K, which are more paramagnetic than those of heart and brain tissues (–1.932×10 -5 and –6.928×10 -6 , respectively).…”
Section: Resultsmentioning
confidence: 99%
“…In addition, most biological tissues are typically regarded as diamagnetic. For instance, human tissue is weakly diamagnetic with a small volume (static) magnetic susceptibility of the order of (SI units), which allows the magnetic field to penetrate into it ( 87 , 88 ). However, the magnetic susceptibility of a tissue can vary depending on the frequency range of the applied magnetic field ( 89 ).…”
Section: Methodsmentioning
confidence: 99%
“…Here, µ r describes the relative permeability of a medium. For example, for blood and air, µ r is approximately 1 [65]. Aside from the magnetic field, the blood flow and properties of SPIONs also play an essential role in the performance of particle steering.…”
Section: Forces On Spionsmentioning
confidence: 99%
“…while integrating over the whole area cross-section of the vessel. Since the relative permeability of tissue and blood is approximately 1 [65], only the permeability of vacuum µ 0 is taken into account for the medium of the background flow.…”
Section: Evaluation Of the Spion Distributionmentioning
confidence: 99%