2017
DOI: 10.1007/s40846-017-0337-y
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the Mechanical Behavior of Polyester Meshes for Abdominal Surgery: A Preliminary Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 36 publications
0
5
0
Order By: Relevance
“…Statistical analysis reveals that sterilization does not affect the overall mechanical properties of industrial nets at physiological strain levels ( P value >0.05). Indeed, even though polymer mechanical properties are probably changed after sterilization, the mechanical behavior of meshes primarily depends on the structural pattern . Even if sterilization slightly affects polymer crystalline degree, with probable consequences of the single fiber mechanical behavior, this modification has no relevant implications on the overall mechanical properties of the net.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Statistical analysis reveals that sterilization does not affect the overall mechanical properties of industrial nets at physiological strain levels ( P value >0.05). Indeed, even though polymer mechanical properties are probably changed after sterilization, the mechanical behavior of meshes primarily depends on the structural pattern . Even if sterilization slightly affects polymer crystalline degree, with probable consequences of the single fiber mechanical behavior, this modification has no relevant implications on the overall mechanical properties of the net.…”
Section: Resultsmentioning
confidence: 99%
“…Ambroziak et al . and Todros et al . characterized the mechanical properties of industrial polyester nets via uniaxial tensile testing in two orthogonal directions.…”
Section: Introductionmentioning
confidence: 99%
“…The elastomer 300 SIL 50-BL is a silicone film of 1.5 mm thickness and was provided by Comitec SNC (Como, Italy). The synthetic mesh is an industrial net (manufactured by Edilacilia, Rome, Italy) already characterized in the literature [18,28].…”
Section: Methodsmentioning
confidence: 99%
“…Indeed, strain gauges need to be physically attached to the specimen and their weight and positioning may influence the mechanical response of the sample [15]. To overcome these disadvantages, non-contact extensometers using a digital video camera and various digital image processing algorithms able to track marker motions [16][17][18] have been widely adopted. Also non-contact techniques still present some limitations, since the accuracy of the markers-tracking and its post-processing can introduce errors.…”
Section: Introductionmentioning
confidence: 99%
“…However, due to the high cost of the third-generation meshes, their wide use is limited. A possibility to utilize a cheaper alternative for commercially available meshes was investigated by Todros et al [ 155 ], who compared the properties of two multifilament industrial nests versus a surgical mesh (Parietex™ Lightweight Monofilament Mesh). All materials were made of PET polyester.…”
Section: Surgical Implants (Suture Materials Tissue Adhesives Surgica...mentioning
confidence: 99%