Investigation of Thermal Characterization of a Thermally Enhanced FC-PBGA Assembly

Abstract: In this paper, three-dimensional finite element analysis using the commercial ANSYS software is performed to study the thermal performance of a thermally enhanced FC-PBGA (flip-chip plastic ball grid array) assembly in both natural and forced convection environments. The thermally enhanced FC-PBGA assembly is a basic FC-PBGA assembly with a lid attached on top, after which an extruded-fin heatsink is attached on the top of the lid. The finite element model is complete enough to include key elements such as bum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…This could be because of the fact that their heat capacities/thermal conductivities differ, which will result in their uneven heating up (Kim et al , 2015). The thermal conductivity of an FR4 substrate is very low and varies from 0.25 W/m·K (Mauney and Qian, 2007) to 0.35 W/m·K (Lin et al , 2013), whereas for copper, the values are much higher 355 W/m·K (Mauney and Qian, 2007) or 398 W/m·K (Lin et al , 2013). However, the specific heat capacity of copper is around 385 J/kg·K, whereas for laminate it is 880 J/kg·K (Wong, 2010) − 1,210 J/kg·K (Backryd and Elden, 2006).…”
Section: Discussionmentioning
confidence: 99%
“…This could be because of the fact that their heat capacities/thermal conductivities differ, which will result in their uneven heating up (Kim et al , 2015). The thermal conductivity of an FR4 substrate is very low and varies from 0.25 W/m·K (Mauney and Qian, 2007) to 0.35 W/m·K (Lin et al , 2013), whereas for copper, the values are much higher 355 W/m·K (Mauney and Qian, 2007) or 398 W/m·K (Lin et al , 2013). However, the specific heat capacity of copper is around 385 J/kg·K, whereas for laminate it is 880 J/kg·K (Wong, 2010) − 1,210 J/kg·K (Backryd and Elden, 2006).…”
Section: Discussionmentioning
confidence: 99%
“…Each network port has an eight-lane 25 Gbps SerDes interface. HFI-E adopts FC-PBGA [7] packaging technology and supplies 692 pins. The die size of HFI-E is 10 mm 10 mm.…”
Section: Proprietary Interconnectmentioning
confidence: 99%