2007
DOI: 10.1063/1.2731440
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of water evolution and transport in fuel cells with high resolution synchrotron x-ray radiography

Abstract: Articles you may be interested inAn evaluation of high energy bremsstrahlung background in point-projection x-ray radiography experimentsa) Rev. Sci. Instrum. 83, 10E528 (2012); 10.1063/1.4738649 High-energy, high-resolution x-ray imaging on the Trident short-pulse laser facilitya) Rev. Sci. Instrum. 79, 10E905 (2008); 10.1063/1.2965012Cross-sectional insight in the water evolution and transport in polymer electrolyte fuel cellsThe authors report on in situ investigations of liquid water evolution and transpor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

7
210
0
1

Year Published

2008
2008
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 340 publications
(218 citation statements)
references
References 20 publications
7
210
0
1
Order By: Relevance
“…To account for the effects of the ribs and channels, an effective DM-length multiplier for a rib-to-channel ratio of 1:1 is used (i.e., 1.6x) as described by Weber [88]. Furthermore, the interface between the flowfield gas channel and the GDL can become controlling and is complex [37,47,83,89], although by examining only steady-state behavior, the transient and droplet aspects can be more-or-less ignored.…”
Section: Updated Porous-medium Model and Modeling Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…To account for the effects of the ribs and channels, an effective DM-length multiplier for a rib-to-channel ratio of 1:1 is used (i.e., 1.6x) as described by Weber [88]. Furthermore, the interface between the flowfield gas channel and the GDL can become controlling and is complex [37,47,83,89], although by examining only steady-state behavior, the transient and droplet aspects can be more-or-less ignored.…”
Section: Updated Porous-medium Model and Modeling Methodologymentioning
confidence: 99%
“…In addition to ex-situ analyses, neutron [42][43][44][45] and other imaging techniques [46][47][48][49] have begun to allow one to see the in-situ DM water profiles with increasingly better resolution.…”
Section: Introductionmentioning
confidence: 99%
“…They studied pore size distributions but also size, shape and orientation of the pores. Many groups concentrate their investigations on liquid water transport [10,11] because this is a key functionality of the GDL when PEFCs are operated below 100 • C.…”
Section: Introductionmentioning
confidence: 99%
“…For fuel cell flow simulation in a porous layer and pore analysis, representative binary models are required which define the internal solid-void boundaries in a GDL structure. Therefore, it is necessary to threshold the greyscale images acquired from X-ray tomography in order to produce binary images (Manke et al, 2007;Feser et al, 2006;Hung et al, 2008).…”
Section: Introductionmentioning
confidence: 99%