Investigation on Ageing Parameters of a Thermally Accelerated Aged Paper-Oil-Insulation in a Hermetically Sealed System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
2
0
2

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 7 publications
0
2
0
2
Order By: Relevance
“…The oils are the non-inhibited Oil A and the inhibited Oil B with a mineral oil base. Furthermore, the oil of the newest generation Oil C is used, which is obtained from natural gas [28][29][30]. The used esters are the synthetic ester Ester A and the natural esters Ester B and Ester C, which are based on rapeseed oil and soybean oil [31].…”
Section: Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…The oils are the non-inhibited Oil A and the inhibited Oil B with a mineral oil base. Furthermore, the oil of the newest generation Oil C is used, which is obtained from natural gas [28][29][30]. The used esters are the synthetic ester Ester A and the natural esters Ester B and Ester C, which are based on rapeseed oil and soybean oil [31].…”
Section: Samplesmentioning
confidence: 99%
“…The used esters are the synthetic ester Ester A and the natural esters Ester B and Ester C, which are based on rapeseed oil and soybean oil [31]. This contribution provides a deeper study as well as a detailed review of a first series of investigations in which aging behavior was performed in a hermetic and free-breathing transformer using Oil A, B, and C [28,29] and a second series of investigations in which a hermetic transformer was replicated using Ester A, B, and C [31].…”
Section: Samplesmentioning
confidence: 99%
“…De acordo com as estatísticas, falhas do transformador causadas pelo envelhecimento do isolamento interno são responsáveis por uma parte significativa dos acidentes com transformadores. Portanto, é essencial investigar as características de envelhecimento do sistema de isolamento com o objetivo de uma avaliação de vida melhorada (MÜNSTER et al, 2018).…”
Section: Influências No Prazo De Vida Do Papel De Isolamentounclassified
“…O envelhecimento de papel isolante, que consiste de celulose, é caracterizado pelo grau de polimerização (GP), o número médio de monômeros de glicose nas cadeias poliméricas de celulose (MÜNSTER et al, 2018). Normalmente, considera-se que o fim da vida útil dos transformadores é alcançado quando o GP do papel cai para um valor de 200, e sua resistência à tração é de aproximadamente 40 % de seu valor inicial.…”
Section: Influências No Prazo De Vida Do Papel De Isolamentounclassified