IEEE EUROCON 2019 -18th International Conference on Smart Technologies 2019
DOI: 10.1109/eurocon.2019.8861893
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on Partial Discharge Activity inside the Cable Accessories due to Improper Installation of Power Cable Joints

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0
3

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 11 publications
0
3
0
3
Order By: Relevance
“…At the installation site, two sections of cables are connected by cable joints to form a pathway according to specific processes. The pathway primarily includes the (1) conductor, (2) conductor shield, (3) XLPE insulation layer, (4) copper connection tube, (5) semi-conductive self-adhesive tape, (6) insulation shield, (7) stress cone, (8) accessory insulation layer, (9) shielding tube, and (10) accessory semi-conductive layer. The cable operating environment is complex, necessitating waterproof and insect-proof treatments on the outermost part of the joints, such as wrapping with multilayer insulating waterproof tape, steel armor, and armor tape.…”
Section: Cable Joint Size and Materials Parametersmentioning
confidence: 99%
“…At the installation site, two sections of cables are connected by cable joints to form a pathway according to specific processes. The pathway primarily includes the (1) conductor, (2) conductor shield, (3) XLPE insulation layer, (4) copper connection tube, (5) semi-conductive self-adhesive tape, (6) insulation shield, (7) stress cone, (8) accessory insulation layer, (9) shielding tube, and (10) accessory semi-conductive layer. The cable operating environment is complex, necessitating waterproof and insect-proof treatments on the outermost part of the joints, such as wrapping with multilayer insulating waterproof tape, steel armor, and armor tape.…”
Section: Cable Joint Size and Materials Parametersmentioning
confidence: 99%
“…No estudo realizado por Batalović et al (2019), foi analisado um cabo XLPE de 35 kV, com cerca de 5 metros de comprimento, por meio de simulações computacionais via métodos de elementos finitos, além do teste convencional offline de medição de DPs a partir de uma fonte secundária de tensão. Em ambas situações foram analisadas a influência da presença de partículas condutoras que possam contaminar a isolação do cabo e acessórios, gerando consequentemente degradação do material devido a descargas superficiais, visto que ocorre um incremento do campo elétrico no local de defeito.…”
Section: Estudo Do Efeito De Dp Em Cabos E Acessórios De Média Tensãounclassified
“…2004). Cerca de 60% destas falhas ocorrem devido a defeitos internos do isolamento dos cabos, sendo que o restante está relacionado a influencias externas, como por exemplo, atividades de escavação em regiões próximas as instalações dos cabos (Batalović et al 2019).…”
Section: Introductionunclassified
See 1 more Smart Citation
“…The primary cause of power cable failure is the breakdown of cable insulation, leading to insulation damage [3][4][5]. Many cable system failures stem from manufacturing issues, such as voids, insulation contamination, improper armour material selection, armour protrusion, and improper jacket selection [6]. These factors exacerbate local stress, leading to premature failure or an accelerated aging process.…”
Section: Introductionmentioning
confidence: 99%