2018
DOI: 10.1016/j.apenergy.2018.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on the daylight and overall energy performance of semi-transparent photovoltaic facades in cold climatic regions of China

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
17
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 52 publications
(18 citation statements)
references
References 21 publications
1
17
0
Order By: Relevance
“…In the evening the solar radiation drops abruptly from 5 pm to 6 pm additionally due to the shadding e ect. is observation agrees with the author Cheng et al [41] in climatic regions of China were shading has an e ect on power generation because during shading there is drop of solar irradiance. Also, the uctuations of monitored parameters were due to the change in environmental conditions caused by either increased or decreased wind speed, unprolonged cloud cover or irradiance uctuations were also observed by [42] in climatic condition of Tanzania.…”
Section: Testing Of Electrical and Opticalsupporting
confidence: 92%
“…In the evening the solar radiation drops abruptly from 5 pm to 6 pm additionally due to the shadding e ect. is observation agrees with the author Cheng et al [41] in climatic regions of China were shading has an e ect on power generation because during shading there is drop of solar irradiance. Also, the uctuations of monitored parameters were due to the change in environmental conditions caused by either increased or decreased wind speed, unprolonged cloud cover or irradiance uctuations were also observed by [42] in climatic condition of Tanzania.…”
Section: Testing Of Electrical and Opticalsupporting
confidence: 92%
“…The dynamic daylight evaluation index has been widely used in the recent research on daylight performance, such as DA, sDA, UDI, and ASE. The DA index was originally proposed by the Swiss Electric Association in 1989 and was further developed to measure the percentage of occupied hours [55]. UDI is defined as the illuminance falling in the range of 100-2000 lx [56].…”
Section: Authormentioning
confidence: 99%
“…It must be reminded that DAYSIM does not consider many important aspects of the light analysis of real light pipes (e.g., the diffuser part). DAYSIM is a validated daylight analysis software [41][42][43][44][45][46][47] that calculates the annual availability of daylight in buildings based on RADIANCE raytracer backward, and it is able to calculate the mentioned daylight indices. The simulated case study is described in Section 3.3.…”
Section: The Simulation Softwarementioning
confidence: 99%