2014
DOI: 10.1016/j.csite.2014.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Investigations of waste heat recovery from bulk milk cooler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Pipe heat exchangers produce a yield of 13,100 kWh of electric energy annually from every thousand litres of milk produced daily [5]. Similar results were obtained by Sapali et al [25,26]. In their experiments, they had 53-65% of recovery of lost heat with milk cooling.…”
Section: Discussionmentioning
confidence: 52%
“…Pipe heat exchangers produce a yield of 13,100 kWh of electric energy annually from every thousand litres of milk produced daily [5]. Similar results were obtained by Sapali et al [25,26]. In their experiments, they had 53-65% of recovery of lost heat with milk cooling.…”
Section: Discussionmentioning
confidence: 52%
“…Since the thermal resistance is situated at the flue gases side, the air volume of the flue gases affects the value of K substantially. The larger the flue gases volume, the higher the value of K , and the larger the obtainable heat energy . If the heat energy required by the manufacturing process drops and the flue gases heat extraction requirement drops, then it will be necessary to control the proportional valve (MV‐5) to limit and reduce the flow of hot water entering the ECO, so as to reduce the amount of heat extracted ( Q ).…”
Section: Case Studymentioning
confidence: 99%
“…The larger the flue gases volume, the higher the value of K, and the larger the obtainable heat energy. 20 If the heat energy required by the manufacturing process drops and the flue gases heat extraction requirement drops, then it will be necessary to control the proportional valve (MV-5) to limit and reduce the flow of hot water entering the ECO, so as to reduce the amount of heat extracted (Q). If the flue gases volume remains unchanged, but the flue gases temperature rises from 160°C to 180°C, then the LMTD of the ECO will be increased accordingly.…”
Section: Computation Of Heat Extractionmentioning
confidence: 99%
“…Locapure and Joshi [3] designed a new system which heat up water using the waste heat from air-conditioning system and improve the coefficient of performance of the system up to 13%. Sapali et al [4] interested by recovering the waste heat from bulk milk coolers for water heating. The COP of the system increased from 3 to 4,8.…”
Section: Introductionmentioning
confidence: 99%