2010
DOI: 10.1111/j.1440-1843.2010.01853.x
|View full text |Cite
|
Sign up to set email alerts
|

Iodine‐123 metaiodobenzylguanidine scintigraphic assessment of pulmonary vascular status in patients with chronic obstructive pulmonary disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 22 publications
0
4
0
1
Order By: Relevance
“…Biddiscombe et al compared different indices among different methods for defining regions and found that PI, defined as peripheral/central aerosol counts normalized by peripheral/central krypton ventilation counts, was less affected by the size of the peripheral and central regions among different methods 25 . Using I‐123 MIBG scintigraphy, Tomonobu et al found in patients with COPD the LMR (the total lung‐to‐upper mediastinum ratio) was not correlated with the pulmonary function parameters measured, including FEV 1 , PaO 2 , DL(CO) or pulmonary artery pressure at rest 26 …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Biddiscombe et al compared different indices among different methods for defining regions and found that PI, defined as peripheral/central aerosol counts normalized by peripheral/central krypton ventilation counts, was less affected by the size of the peripheral and central regions among different methods 25 . Using I‐123 MIBG scintigraphy, Tomonobu et al found in patients with COPD the LMR (the total lung‐to‐upper mediastinum ratio) was not correlated with the pulmonary function parameters measured, including FEV 1 , PaO 2 , DL(CO) or pulmonary artery pressure at rest 26 …”
Section: Discussionmentioning
confidence: 99%
“…25 Using I-123 MIBG scintigraphy, Tomonobu et al found in patients with COPD the LMR (the total lung-to-upper mediastinum ratio) was not correlated with the pulmonary function parameters measured, including FEV 1 , PaO 2 , DL(CO) or pulmonary artery pressure at rest. 26 Theoretically, larger particles tend to deposit at larger lumen. In this study, Ga-68 EDTA aerosols distributed more in central region, with different patterns among the different groups.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Decreased lung uptake of 123I‐MIBG has been demonstrated in patients with COPD as compared with normal subjects. Koizumi and colleagues demonstrated that early lung uptake of 123I‐ MIBG is inversely correlated with increased pulmonary artery pressure during exercise in patients with COPD 38 …”
Section: Clinical Copdmentioning
confidence: 99%
“…МИБГ представляет собой аналог норадреналина, что позволяет наблюдать проявления симпатической денервации миокарда ЛЖ, имеющие известное прогностическое значение у пациентов с хронической сердечной недостаточностью [26,27]. Есть данные о возможности оценки накопления МИБГ в легких, которое снижено у пациентов с ХОБЛ по сравнению с группой нормы [28]. Аналогичных исследований ПЖ, в частности у пациентов с ЛГ, выполнено крайне мало.…”
Section: Introductionunclassified