2019
DOI: 10.1016/j.jhazmat.2019.05.112
|View full text |Cite
|
Sign up to set email alerts
|

Ion exchange collaborating coordination substitution: More efficient Cr(VI) removal performance of a water-stable CuII-MOF material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
35
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 98 publications
(35 citation statements)
references
References 59 publications
0
35
0
Order By: Relevance
“…Therefore, the treatment of acidic wastewater containing Cr(VI) has attracted extensive attention. Many efficient methods have been developed, such as adsorption, [3] photocatalysis, [4] ion exchange [3,5] and membrane filtration. [6] Among these methods, adsorption technology is more fundamental and efficient procedure for removing target pollutants with a high adsorption capacity.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the treatment of acidic wastewater containing Cr(VI) has attracted extensive attention. Many efficient methods have been developed, such as adsorption, [3] photocatalysis, [4] ion exchange [3,5] and membrane filtration. [6] Among these methods, adsorption technology is more fundamental and efficient procedure for removing target pollutants with a high adsorption capacity.…”
Section: Introductionmentioning
confidence: 99%
“…Time-dependent adsorption efficiency (a) and Qe (b) of Cr(VI) (200 mL, 20 mg L À 1 ) at different pH(3,5,7,9,11) in the present of BC/ZnFe 2 O 4 .…”
mentioning
confidence: 99%
“…Dichromate (Cr 2 O 7 2− ) is a well‐known carcinogen anion diffusing rapidly as a result of its wide applications in chromium electroplating, pigment production, metallurgy, leather tanning, etc . Hexavalent chromium is known as toxic or poisonous element even at low concentrations, and WHO has assigned that Cr VI level must be below 0.05 mg L −1 for drinking water . Researches show that Cr VI is significantly more toxic than Cr III .…”
Section: Adsorption Of One Metal Ionmentioning
confidence: 99%
“…[20] To investigate the probablea dsorption mechanism, extended characterization techniques including infrared spectroscopy, PXRD experiments, and X-ray photoelectron spectroscopy (XPS) were conducted. Unfortunately,t he attempts were not successful and larger single crystals could not be obtained.…”
Section: Adsorption Mechanismmentioning
confidence: 99%