1976
DOI: 10.1016/0039-9140(76)80126-9
|View full text |Cite
|
Sign up to set email alerts
|

Ion-exchanger colorimetry—I Micro determination of chromium, iron, copper and cobalt in water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
58
0
3

Year Published

1998
1998
2014
2014

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 169 publications
(61 citation statements)
references
References 11 publications
0
58
0
3
Order By: Relevance
“…To minimize the error caused by the packing state difference of the solid beads in the cell for each measurement, the absorbances of the solid phase were measured at the maximum-absorption wavelength (λ1 nm) and a weak or no-absorption wavelength (λ2 nm), then the difference in the attenuances (ΔA = A(λ1 nm) -A(λ2 nm)) was used for the quantitative analysis of the target analyte. 8,18 Therefore, light attenuances at wavelengths λ1 = 610 nm and λ2 = 750 nm were selected for this measurement, then, ΔA was used for the determination of the total iron.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To minimize the error caused by the packing state difference of the solid beads in the cell for each measurement, the absorbances of the solid phase were measured at the maximum-absorption wavelength (λ1 nm) and a weak or no-absorption wavelength (λ2 nm), then the difference in the attenuances (ΔA = A(λ1 nm) -A(λ2 nm)) was used for the quantitative analysis of the target analyte. 8,18 Therefore, light attenuances at wavelengths λ1 = 610 nm and λ2 = 750 nm were selected for this measurement, then, ΔA was used for the determination of the total iron.…”
Section: Resultsmentioning
confidence: 99%
“…SPS denotes the direct absorption measurement of solid beads on which the colored analyte was adsorbed. 8 Regarding the concentration, the SPS efficiency is significantly greater than that of evaporation concentration. For example, in the solution spectrometric method, an 800-cm 3 boiler water sample has to be evaporated/concentrated to 50 cm 3 by heating for 4 -5 h to obtain a measurable iron concentration.…”
Section: Introductionmentioning
confidence: 97%
“…This method has already been shown to be advantageous for analysis of different metals as well as for their content control in electrolytes, sewage and natural water. [9][10][11][12][13] Moreover, this method is cheap and applicable under field conditions. 14 In a recent study we investigated the ion exchange recovery of nickel from manganese nitrate solutions obtained after the processing of manganese ores.…”
Section: Introductionmentioning
confidence: 99%
“…Solid-phase spectrophotometry (SPS) 3,4 is a methodology that includes the preconcentration of the analyte on a solid, with a previous or simultaneous reaction step to produce a chromogenic compound, and the subsequent measurement of the absorbance in the solid phase. This provides an increase in selectivity and sensitivity to SPS methods in relation to solution methods.…”
mentioning
confidence: 99%
“…The optimization of variables was studied both in the traditional mode ("one-at-a-time") and using Doehlert's design 5 in order to perform a comparative study. Robust regression 6,7 was applied to detect the outliers and for the determination of the upper limit of the calibration graph for the 100 cm 3 sample system. Saturated fractional factorial designs at two levels were used to evaluate the robustness of the proposed method.…”
mentioning