2022
DOI: 10.1016/j.chroma.2022.463502
|View full text |Cite
|
Sign up to set email alerts
|

Ion mobility-mass spectrometry to extend analytical performance in the determination of ergot alkaloids in cereal samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 54 publications
0
9
0
Order By: Relevance
“…As mentioned earlier, CCSbase can be used for CCS prediction of peptides, carbohydrates, lipids, metabolites, and drugs 50,144,147,148,168 . The use of CCSbase has also been reported for the drug molecules metoprolol acid/atenolol acid in water samples by Hinnenkamp et al 173 and for ergot alkaloids (EA) in cereal samples by Carbonell‐Rozas et al 174 Moreover, Yang et al showed that CCSbase presented smaller error than AllCCS with CCS isomer difference of more than 16% on the study of ginsenoside isomers, 172 while in another study, CCSbase showed similar CCS behavior for per‐ and polyfluoroalkyl substances (PFAS) analysis 175 . Interestingly, Lenski et al developed a workflow that combined the CCSbase prediction method with a quantitative structure–retention relationship (QSRR) predictor for the prediction of CCS and RT, respectively, to reduce false positive annotations in nontargeted metabolomics, recently 176 …”
Section: Ccs Modelsmentioning
confidence: 91%
See 1 more Smart Citation
“…As mentioned earlier, CCSbase can be used for CCS prediction of peptides, carbohydrates, lipids, metabolites, and drugs 50,144,147,148,168 . The use of CCSbase has also been reported for the drug molecules metoprolol acid/atenolol acid in water samples by Hinnenkamp et al 173 and for ergot alkaloids (EA) in cereal samples by Carbonell‐Rozas et al 174 Moreover, Yang et al showed that CCSbase presented smaller error than AllCCS with CCS isomer difference of more than 16% on the study of ginsenoside isomers, 172 while in another study, CCSbase showed similar CCS behavior for per‐ and polyfluoroalkyl substances (PFAS) analysis 175 . Interestingly, Lenski et al developed a workflow that combined the CCSbase prediction method with a quantitative structure–retention relationship (QSRR) predictor for the prediction of CCS and RT, respectively, to reduce false positive annotations in nontargeted metabolomics, recently 176 …”
Section: Ccs Modelsmentioning
confidence: 91%
“…50 As mentioned earlier, CCSbase can be used for CCS prediction of peptides, carbohydrates, lipids, metabolites, and drugs. 50,144,147,148,168 The use of CCSbase has also been reported for the drug molecules metoprolol acid/atenolol acid in water samples by Hinnenkamp et al 173 and for ergot alkaloids (EA) in cereal samples by Carbonell-Rozas et al 174 The web server for this model is accessible through CCSondemand (waters.com). Later, the same ML model was compared with QM approaches using MOBCAL on glucuronides.…”
Section: Metccs and Lipidccsmentioning
confidence: 94%
“…The elimination of background interference can also lead to an increased signal-to-noise (S/N) ratio; thus lower LODs for analytes of interest can be obtained, ,, The study of Carbonell-Rozas and co-workers showed that the integration of TWIMS in the LC–MS/MS workflow improves the S/N between 2.5 and 4 times . The decrease in LODs makes it possible to detect contaminants at lower concentrations in environmental samples.…”
Section: Benefits Of Ims and The Derived Ccs In Targeted Suspect And ...mentioning
confidence: 99%
“…Sometimes, isomers can only be separated and identified according to the CCS values of one specific adduct, for example, the ergot alkaloids and their corresponding epimers can be distinguished by the CCS values of their [M + Na] + adduct, but not from the CCS values of their [M + H] + adduct Figure shows the arrival time distributions of aldrin and isodrin; it is obvious to see that similar CCS values were obtained for their [M + H] + adducts, however, the CCS values of M + * ions were significantly different, enabling their unequivocal identification.…”
Section: Benefits Of Ims and The Derived Ccs In Targeted Suspect And ...mentioning
confidence: 99%
“…Bile acids comprise a structurally challenging subclass, due to the presence of numerous hydroxyl group positional and stereochemical isomers, but further incorporation of complementary computational modeling could assist in identification . IM-MS has even seen utility in identifying steroids in food safety applications. Other steroid subclasses that have been profiled using IM-MS have included vitamin D metabolites, glucorocorticoids, and serum estrogens …”
Section: Introductionmentioning
confidence: 99%