Ion Mobility Spectrometer-Fragmenter-Ion Mobility Spectrometer Analogue of a Triple Quadrupole for High-Resolution Ion Analysis at Atmospheric Pressure

Abstract: Two differential mobility analyzers (DMAs) acting as narrow band mobility filters are coupled in series, with a thermal fragmentation cell placed in between, such that parent ions selected in DMA are fragmented in the cell at atmospheric pressure, and their product ions are analyzed on DMA. Additional mass spectrometer analysis is performed for ion identification purposes. A key feature of the tandem DMA is the short residence time (∼0.2 ms) of ions in the analyzer, compared to tens of milliseconds in drift tu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 36 publications
0
15
0
Order By: Relevance
“…Tandem DMA [51] and FAIMS instruments can often be used stand-alone coupled to detectors, such as a condensation particle counter [70] (CPC) or a Raman spectroscopy [71]. In 2018 a tandem DMA cell, modified for fragmentation of highly thermally stable volatile compounds, was coupled to a triple-quadrupole, and then faraday cup detector system [45]. These detectors allowed proof-of-concept for the fragmentation and identification of a variety of explosive compounds through the use of IM alone.…”
Section: A Decade Of Expansionmentioning
confidence: 99%
See 1 more Smart Citation
“…Tandem DMA [51] and FAIMS instruments can often be used stand-alone coupled to detectors, such as a condensation particle counter [70] (CPC) or a Raman spectroscopy [71]. In 2018 a tandem DMA cell, modified for fragmentation of highly thermally stable volatile compounds, was coupled to a triple-quadrupole, and then faraday cup detector system [45]. These detectors allowed proof-of-concept for the fragmentation and identification of a variety of explosive compounds through the use of IM alone.…”
Section: A Decade Of Expansionmentioning
confidence: 99%
“…Astrices represent where there were fewer than 10 publications per year (B) Timeline of advances of IM, IM-MS and Tandem-IM, withthe dating from 1960-2020. References, in chronological order:[16,25,27,29,30,32,33,35,[38][39][40][41][42][43][44][45][46][47][48][49].…”
mentioning
confidence: 99%
“…28,29 Furthermore, although ESI and CD are soft ionization methods, sometimes IMS peaks related to smaller fragments are also observed. [30][31][32][33] Hydration of ions and their fragmentation depend on the structure and basicity of the molecule M. 34 In addition, instrumental parameters and existence of modifier gases (dopants) influence the type of produced ions. [35][36][37] Because IMS is used for opiate alkaloids in both the solid and solution phase, hence, in this work, ionization of pure solids and aqueous solutions of morphine, codeine, and thebaine is studied by APCI-CD-IMS.…”
Section: Introductionmentioning
confidence: 99%
“… 27 However, other ions and larger clusters such as hydrated protonated molecules, MH + (H 2 O) n , and proton‐bound dimers, (M) 2 H + , are also formed 28,29 . Furthermore, although ESI and CD are soft ionization methods, sometimes IMS peaks related to smaller fragments are also observed 30–33 . Hydration of ions and their fragmentation depend on the structure and basicity of the molecule M 34 .…”
Section: Introductionmentioning
confidence: 99%
“…Thus, two possible routes to fragment ions in IMS can be derived. One is simply increasing the absolute temperature T in a fragmenter region. , Fragmenter setups utilizing temperatures of 700 °C have been demonstrated . The second is an increased effective ion temperature T eff by applying high reduced electrical fields.…”
mentioning
confidence: 99%