1990
DOI: 10.1080/10408349008050848
|View full text |Cite
|
Sign up to set email alerts
|

Ion Mobility Spectrometry in Analytical Chemistry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
93
0

Year Published

1998
1998
2015
2015

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 279 publications
(93 citation statements)
references
References 83 publications
0
93
0
Order By: Relevance
“…The quotient of ion velocity and electric field strength is referred to as ion mobility [35]. The mobility, K, is calculated using the measured drift time, t D , of an ion through a specified drift length, l D , under a known electric field, E, using the equation below [1,2]. This ion mobility value is normalised to standard gas density, 2.687×10 19 molecules/cm, corresponding to 273 degree Kelvin and 101325 Pascal, and reported as the reduced ion mobility, K 0 [35][36][37].…”
Section: Ion Mobility Spectrometrymentioning
confidence: 99%
See 1 more Smart Citation
“…The quotient of ion velocity and electric field strength is referred to as ion mobility [35]. The mobility, K, is calculated using the measured drift time, t D , of an ion through a specified drift length, l D , under a known electric field, E, using the equation below [1,2]. This ion mobility value is normalised to standard gas density, 2.687×10 19 molecules/cm, corresponding to 273 degree Kelvin and 101325 Pascal, and reported as the reduced ion mobility, K 0 [35][36][37].…”
Section: Ion Mobility Spectrometrymentioning
confidence: 99%
“…Over the past few decades, ion-mobility spectrometry has evolved into an inexpensive and powerful technique for the detection of trace compounds in the lower ng/L (ppb v ) down to pg/L (ppt v ) range, for direct monitoring of specific compound classes such as chemical warfare agents and drugs of abuse [1,2]. However, in recent years, ion mobility spectrometers are increasingly in demand for new applications specifically on biological samples (cells, fungi, bacteria) [3][4][5][6][7][8][9][10][11][12], in medicine (diagnosis, therapy and medication control e.g.…”
Section: Introductionmentioning
confidence: 99%
“…The development of IMS instrumentation [20,[33][34][35][36][37][38][39][40], theory [41][42][43][44][45], and applications [46][47][48][49][50] is described in the literature. Here, only a brief description of the IMS-MS instrument and its operation is presented.…”
Section: Ims-ms Measurementsmentioning
confidence: 99%
“…The introduction of IMS lies almost half a century back, when ion mobility spectrometers were used for military purpose (e.g. chemical war fare agents) and later on in security sensitive domains for detection of explosives and drugs [1,2]. In the course of time IMS found its way to civilian applications.…”
Section: Introductionmentioning
confidence: 99%