1991
DOI: 10.1016/0168-1176(91)80080-7
|View full text |Cite
|
Sign up to set email alerts
|

Ion/molecule reactions of atmospheric ions with dimethyl-methylphosphonate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

12
13
0

Year Published

2009
2009
2013
2013

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(25 citation statements)
references
References 11 publications
12
13
0
Order By: Relevance
“…19 The current SIFT rate constant is close to the collision rate constant value, but it is 4 times greater than the previous SIFDT experimental value. 19 The current experiments use a very dilute mixture of DMMP in helium that reacts with the selected reactant ion for a fixed reaction time while the flow of the mixture is varied. The Chatterjee et al experiments, on the other hand, have used a neat DMMP sample cooled in a dry ice bath at a concentration determined by measuring the pressure of DMMP with a capacitance manometer.…”
Section: Resultssupporting
confidence: 51%
See 3 more Smart Citations
“…19 The current SIFT rate constant is close to the collision rate constant value, but it is 4 times greater than the previous SIFDT experimental value. 19 The current experiments use a very dilute mixture of DMMP in helium that reacts with the selected reactant ion for a fixed reaction time while the flow of the mixture is varied. The Chatterjee et al experiments, on the other hand, have used a neat DMMP sample cooled in a dry ice bath at a concentration determined by measuring the pressure of DMMP with a capacitance manometer.…”
Section: Resultssupporting
confidence: 51%
“…14 Lum and Grabowski have studied negative ion reactions with DMMP in a flowing afterglow to compare the reactivity of the P-O and C-O bonds, 18 while Johnsen and co-workers have examined the reactions of several air plasma cations with DMMP in a selected ion flow drift tube (SIFDT). 19 CIMS detection of CWAs benefits from not having to pretreat the gas sample to be analyzed, only requiring the production of easily generated reactant ions that have both large rate constants and unique product ion distributions upon reaction with CWAs to achieve sensitive and selective detection. To find new ion-molecule reactions that meet these two criteria for the GX series agents, a study of experimental rate constants and product ion branching ratios has been conducted using a selected ion flow tube (SIFT) at 298 K for a variety of positive and negative ions reacting with the GX structural surrogate, DMMP.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…A field in the direction of the mass spectrometer inlet transports the (Beauchamp, et al, 2008) ions formed to the inlet. The concept of proton transfer reaction for mass spectrometry is well known and has already been used in the 1960s (Moran & Hamill, 1963) for the investigation of ion-molecule reactions (Chatterjee et al, 1991). PTR-MS in the configuration shown in Figure 5 has been developed by Hansel et al (1995).…”
Section: Proton Transfer Reaction Mass Spectrometrymentioning
confidence: 99%