Ion-optics calculations of the LLNL AMS system for biochemical 14C measurements

Abstract: A dedicated AMS system for biochemical 14 C measurements is being built at Center for Accelerator Mass Spectrometry. The system is centered around a National

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2000
2000
2010
2010

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 5 publications
1
10
0
Order By: Relevance
“…The material was known to be 14 C-dead from 4 + AMS measurements at 6.5 MV. Count rates equivalent to 30 pMC (T Ognibene, personal communication) were observed on a small NEC AMS system at LLNL (Ognibene et al 2000), similar to ours but with poorer vacuum in the HE magnet. Scaling the results for our system to samples of normal 13 C content, we can expect backgrounds in the 0.05-0.1 pMC range.…”
Section: Scatteringsupporting
confidence: 79%
“…The material was known to be 14 C-dead from 4 + AMS measurements at 6.5 MV. Count rates equivalent to 30 pMC (T Ognibene, personal communication) were observed on a small NEC AMS system at LLNL (Ognibene et al 2000), similar to ours but with poorer vacuum in the HE magnet. Scaling the results for our system to samples of normal 13 C content, we can expect backgrounds in the 0.05-0.1 pMC range.…”
Section: Scatteringsupporting
confidence: 79%
“…This spectrometer was carefully designed for maximal loss-free transmission [40] of ions produced by the uniquely intense LLNL ion source [41] from samples reduced to carbon with a high-throughput process [29]. However, most analytical properties described here arise from the fundamental isotope ratio nature of an AMS measurement on a homogeneous sample and will be applicable to most well-designed and operated AMS spectrometers.…”
Section: Resultsmentioning
confidence: 99%
“…It contains a 1MV NEC Pelletron accelerator, but was assembled from NEC and LLNL components rather than purchased as a unit. The ion optics of the spectrometer (Ognibene et al 2000) were designed to accept the output of the LLNL high-intensity ion source (Southon and Roberts 2000), which is routinely operated at ion currents of 100-250 µA 12 C -, with 14 C count rates of 200-400 cps for Modern samples. These high count rates make possible detailed testing of equivalence between counting statistics and measurement precisions within reasonable time periods.…”
Section: Uncertainties In Amsmentioning
confidence: 99%