2012
DOI: 10.1016/j.aca.2012.06.027
|View full text |Cite
|
Sign up to set email alerts
|

Ion-pair sorptive extraction of perfluorinated compounds from water with low-cost polymeric materials: Polyethersulfone vs polydimethylsiloxane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
12
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(14 citation statements)
references
References 38 publications
1
12
0
1
Order By: Relevance
“…33%) for the long chain PFCAs (PFNA and PFDA), short chain PFCAs showed a higher affinity for the aqueous media. The same trend was observed by Villaverde-de-Saá et al [44] during the preconcentration of water samples.…”
Section: Optimization Of the Polymeric Based Preconcentration And Clesupporting
confidence: 81%
See 1 more Smart Citation
“…33%) for the long chain PFCAs (PFNA and PFDA), short chain PFCAs showed a higher affinity for the aqueous media. The same trend was observed by Villaverde-de-Saá et al [44] during the preconcentration of water samples.…”
Section: Optimization Of the Polymeric Based Preconcentration And Clesupporting
confidence: 81%
“…Alzaga and Bayona [37] and Villaverde-de-Saá et al [44] employed TBA as ion-pair reagent to preconcentrate PFASs in aqueous matrices and improved the solid phase micro extraction (SPME) and solid (polymeric material) liquid extraction extractability. Regarding the polymeric material, PES was firstly proved as a good alternative for the extraction of polar analytes [45] and, later, for PFASs in water samples [44]. However, in the present work, the purpose was not the mere preconcentration but to find an alternative clean-up step for FUSLE extracts of solid samples.…”
Section: Optimization Of the Polymeric Based Preconcentration And Clementioning
confidence: 99%
“…One of the most used strategies for the determination of trace organic compounds in liquid matrices is centered on the miniaturization and automation of sample preparation techniques [11][12][13][14][15]. In addition to the well-established microextraction techniques, mainly solid phase microextraction (SPME) [11,[16][17][18] and stir bar sorptive extraction (SBSE) [19][20][21][22][23][24][25][26][27], polyethersulfone (PES) polymer has emerged recently [14,28,29] as a very suitable choice for the extraction of polar species, improving significantly the extraction efficiencies provided by other polymeric materials such as polydimethylsiloxane (PDMS), among others.…”
Section: Introductionmentioning
confidence: 99%
“…0,07-6,88 bitarteko log K ow balioa duten analitoetarako egokia dela frogatu da [45]. Musketa fragantziak, APak, hormonak, konposatu farmazeutikoak, PEak, pestizidak, konposatu perfluorinatuak ur-laginetatik erauztea lortu dute hainbat ikertzailek [25,45,51]. PES polimeroak, polartasun desberdineko konposatuak erauzteaz gain, kostu baxua (~0,05 €/analisi) du komertzialki saltzen diren hagatxoekin alderatuz.…”
Section: Lagin Likidoakunclassified