2019
DOI: 10.1109/tdei.2019.008066
|View full text |Cite
|
Sign up to set email alerts
|

Ionization and attachment coefficients in C4F7N/N2 gas mixtures for use as a replacement to SF6

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 24 publications
(18 citation statements)
references
References 21 publications
0
18
0
Order By: Relevance
“…The experiments were carried out on an SST apparatus setup in Wuhan University, which the details have been described in previous work [18,19]. The reliability of this SST apparatus has been verified by experiments on known gases such as SF 6 and N 2 , which showed this SST apparatus has great measurement accuracy (<2%) [19].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The experiments were carried out on an SST apparatus setup in Wuhan University, which the details have been described in previous work [18,19]. The reliability of this SST apparatus has been verified by experiments on known gases such as SF 6 and N 2 , which showed this SST apparatus has great measurement accuracy (<2%) [19].…”
Section: Methodsmentioning
confidence: 99%
“…The normalized effective ionization coefficient (α − η)/N of C 4 F 7 N, in a range of E/N from 750 to 1150 Td, at 20 • C was obtained as well. Figure 4 presents the value (α − η)/N as a function of E/N in C 4 F 7 N, and its comparisons with SF 6 [3], c-C 4 F 8 [4], CF 3 I [7], C 4 F 7 N [13,14], and C 4 F 7 N/N 2 mixtures [18] are reported. Notably, the E/N of C 4 F 7 N was much greater than other kinds of gases for the same (α − η)/N, which suggests that the insulation ability of C 4 F 7 N is much stronger.…”
Section: Effective Ionization Coefficientsmentioning
confidence: 99%
“…The measurements of the C 4 F 7 N/CO 2 mixtures were performed on the SST apparatus setup in Wuhan University [13], [14]. The accuracy of the measurement is less than 2%.…”
Section: Methodsmentioning
confidence: 99%
“…All equipment of the SST experimental platform have been verified by the Hubei Institute of Metrology and Testing Technology. As described in the previous work [13], the apparatus consist 5 parts, and the one of the important parts is the vacuum system. The background vacuum degree in the ionization chamber can reach approximately 1.0 × 10 −5 Pa at 20 • C. The low leak rate of pressure as 0.07 Pa/h guarantee the stable gas pressure as 500 ∼ 2000 Pa during the SST experiments.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation