2022
DOI: 10.1039/d1sd00055a
|View full text |Cite
|
Sign up to set email alerts
|

Ionophore-based ion-selective electrodes: signal transduction and amplification from potentiometry

Abstract: Ionophore-based ion-selective electrodes (ISEs) are traditionally operated with potentiometry by measuring the open circuit potential against a reference electrode. However, the sensitivity of ISEs is limited by the well-known Nernstian...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 76 publications
0
13
0
Order By: Relevance
“…The electrode potential changes linearly in the Nernst response region. [1][2][3][4][5] A growing number of new theoretical and application achievements in potentiometry has appeared worldwide. One of the research directions in the eld of potentiometry is the development of new potentiometric sensors to obtain the most favourable analytical parameters.…”
Section: Introductionmentioning
confidence: 99%
“…The electrode potential changes linearly in the Nernst response region. [1][2][3][4][5] A growing number of new theoretical and application achievements in potentiometry has appeared worldwide. One of the research directions in the eld of potentiometry is the development of new potentiometric sensors to obtain the most favourable analytical parameters.…”
Section: Introductionmentioning
confidence: 99%
“…5–9 Recently, the applications of ISEs have been enhanced by the conversion of electric potential in an ISE into other optical 10,11 or electrochemical 12,13 signals to improve sensitivity. 14…”
Section: Introductionmentioning
confidence: 99%
“…[5][6][7][8][9] Recently, the applications of ISEs have been enhanced by the conversion of electric potential in an ISE into other optical 10,11 or electrochemical 12,13 signals to improve sensitivity. 14 The use of microfluidic paper-based substrates for solution sampling rather than the traditional beaker-based measure-ments adds advantages to the analytical protocol of specific sample types, e.g. it requires only a small sample volume and allows analysis of samples consisting of high solid-to-liquid ratios.…”
Section: Introductionmentioning
confidence: 99%
“…5 Also, to improve the sensitivity limits of potentiometric ISEs, various signal transduction approaches have been studied. 6 In general, ISEs with a low detection limit and high ion selectivity are desired. One way to lower the detection limit is to reduce transmembrane ion fluxes.…”
mentioning
confidence: 99%
“…As for the sensing mode, sensing protocols other than zero-current potentiometry have also been used with ISEs, such as chronopotentiometry, chronoamperometry, and coulometry . Also, to improve the sensitivity limits of potentiometric ISEs, various signal transduction approaches have been studied …”
mentioning