2019
DOI: 10.1016/j.aca.2019.03.019
|View full text |Cite
|
Sign up to set email alerts
|

Isolation and identification of Listeria monocytogenes utilizing DC insulator-based dielectrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
49
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 43 publications
(49 citation statements)
references
References 68 publications
0
49
0
Order By: Relevance
“…Each strain was tested separately in various devices of the same design. Both strains produced a pattern of collected cells appearing as distinct arcs near a 27 µm gate at appropriate applied voltages (Figures 1A, 2; Jones et al, 2014Jones et al, , 2015Crowther et al, 2019). With 1600 V applied, sv.…”
Section: Resultsmentioning
confidence: 98%
See 2 more Smart Citations
“…Each strain was tested separately in various devices of the same design. Both strains produced a pattern of collected cells appearing as distinct arcs near a 27 µm gate at appropriate applied voltages (Figures 1A, 2; Jones et al, 2014Jones et al, , 2015Crowther et al, 2019). With 1600 V applied, sv.…”
Section: Resultsmentioning
confidence: 98%
“…where ε m is the permittivity of the medium, ζ p is the EK (zeta) potential of the particle, and ζ m is the EK (zeta) potential of the medium/wall system. The value of µ EK was determined for both strains by particle tracking velocimetry (Crowther et al, 2019;Hilton and Hayes, 2019) at various applied voltages based on: where v EK is the velocity of the particle in an open channel. The capture of the particles can be observed when the flux of particles ( j ) is zero in the channel with the condition:…”
Section: Theorymentioning
confidence: 99%
See 1 more Smart Citation
“… to fabricate 60 µm high gold electrodes in a 150 µm high channel. For these electrodes, however, the main shortcoming is that the sample and suspending medium will be contaminated by direct contacting with the conductive microelectrodes . Recently, electrodes made of doped PDMS and doped silicon are becoming popular, which can eliminate the sample contamination problem caused by carbon and metal electrodes.…”
Section: Configurations Of Electrodes and Dep Devicesmentioning
confidence: 99%
“…However, this approach makes use of very costly image acquisition and analysis equipment [52]. There are also insulator‐based DEP approaches that make use of field gradients created around insulating objects placed within channels [53–56]. The insulator‐based DEP approaches also use microscopes and require image analysis.…”
Section: Introductionmentioning
confidence: 99%