1982
DOI: 10.1021/ac00245a007
|View full text |Cite
|
Sign up to set email alerts
|

Isolation of polycyclic aromatic hydrocarbons in air particulate matter by liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

1983
1983
1995
1995

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…The interferences among the numerous components in a complex mixture can be minimized or eliminated by use of preseparation or cleanup procedures. Among various separation procedures, high-performance liquid chromatography (HPLC) has definite advantages which have led to its increasing use in the analysis of environmental samples (2,(4)(5)(6)(7)(8). High separation efficiency, good reproducibility, and recovery are more easily obtained in HPLC separation.…”
mentioning
confidence: 99%
“…The interferences among the numerous components in a complex mixture can be minimized or eliminated by use of preseparation or cleanup procedures. Among various separation procedures, high-performance liquid chromatography (HPLC) has definite advantages which have led to its increasing use in the analysis of environmental samples (2,(4)(5)(6)(7)(8). High separation efficiency, good reproducibility, and recovery are more easily obtained in HPLC separation.…”
mentioning
confidence: 99%
“…GC-MS has been used for PAH analyses in biological samples (Lintas et al, 1979;Grimmer and Bóhnke, 1975). Both HPLC and GC have been used together either for HPLC fractionation prior to GC analysis (Romanowski et al, 1982) or for comparative purposes (Eadie et al, 1982). In this work we use both techniques for the determination of selected PAH in a variety of fish and meat samples.…”
mentioning
confidence: 99%
“…Based on the large number of application papers recently published, CC/GC-MS is currently the method of choice for the determination of PAC in complex environmental samples (18,(38)(39)(40)(41)(42)(75)(76)(77)(78)(79)(80)(81)(82)(83)(84). The combination of the high chromatographic resolution of CC/GC and the rapid scanning capabilities of an appropriate mass spectrometer provides a highly selective tool for the qualitative determination of components of complex samples.…”
Section: Capillary Column Gc-ms In Pac Analysesmentioning
confidence: 99%