2012
DOI: 10.1039/c2ja30153a
|View full text |Cite
|
Sign up to set email alerts
|

Isotope abundance ratio measurements by inductively coupled plasma-sector field mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
56
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(57 citation statements)
references
References 167 publications
(424 reference statements)
1
56
0
Order By: Relevance
“…20,23 The Russell (kinetic) law 34 was found suitable for the correction of mass bias, with the version revised by Baxter found most successful. These corrected ratios are indicated hereafter as ( x Ni/ 58 Ni) Cu corr and ( x Ni/ 58 Ni) Ni corr , respectively.…”
Section: Correction For Instrumental Mass Discriminationmentioning
confidence: 99%
See 1 more Smart Citation
“…20,23 The Russell (kinetic) law 34 was found suitable for the correction of mass bias, with the version revised by Baxter found most successful. These corrected ratios are indicated hereafter as ( x Ni/ 58 Ni) Cu corr and ( x Ni/ 58 Ni) Ni corr , respectively.…”
Section: Correction For Instrumental Mass Discriminationmentioning
confidence: 99%
“…8 Ni isotopes were recently also used to track the process of continental weathering 12,13 . 13,18,19 At the same time, mass-dependent fractionation of Ni isotopes occurring during the evolution of meteorite parent bodies can be quantified and cancelled out using mass-fractionation laws 20 and one pair of Ni isotopes that are not prone to non massdependent effects as internal standard. 13,18,19 At the same time, mass-dependent fractionation of Ni isotopes occurring during the evolution of meteorite parent bodies can be quantified and cancelled out using mass-fractionation laws 20 and one pair of Ni isotopes that are not prone to non massdependent effects as internal standard.…”
Section: Introductionmentioning
confidence: 99%
“…Multi‐collector inductively coupled plasma mass spectrometry (MC‐ICP‐MS) has been widely used to measure metal stable isotopic compositions in recent decades (e.g …”
Section: Introductionmentioning
confidence: 99%
“…The observed 206 Pb/ 204 Pb, 208 Pb/ 206 Pb, 206 Pb/ 207 Pb, and 208 Pb/ 204 Pb ratios were normalized using the 205 Tl/ 203 Tl ratio of Tl isotope reference NIST SRM 997 ( 205 Tl/ 203 Tl = 2.3871), added to the sample prior to analysis (Tanimizu and Ishikawa, 2006). The relationship between the observed and normalized Pb and Tl isotope ratios was calculated using the exponential law (Baxter et al, 2012;Albarède et al, 2004). 87 Sr/ 86 Sr ratios were normalized to 86 Sr/ 88 Sr = 0.1194.…”
Section: Radiogenic Isotopesmentioning
confidence: 99%