1996
DOI: 10.1111/j.1540-8159.1996.tb03228.x
|View full text |Cite
|
Sign up to set email alerts
|

Italian Experience with AutoCapture in Conjunction with a Membrane Lead

Abstract: AutoCapture is a programmable feature of the Pacesetter Microny SR + 2425T VVIR pacemaker, which provides for the automatic capture verification, increase in output in the presence of noncapture and threshold searching, with adjustment of output settings. The effectiveness of this unit in conjunction with the Membrane models 1400T and 1401T bipolar endocardial leads was studied in 54 patients followed at 19 Italian Centers. The patients were randomized at the time of implantation to receive either the model 14… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

1998
1998
2019
2019

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 28 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…The study was designed to calculate the bat tery current drain and device longevity by evalu ating pacing output during long-term follow-up of a group of patients who had received a Microny SR+ 2425T W I R pacemaker, a single chamber rate modulated (SSIR) pulse generator (0.35 Ah battery capacity) with Autocapture as a pro-grammable option used for automatic adaptation of device output to stimulation threshold and con sistent ventricular capture. 3,4 All patients had also received low polarization, low threshold bipolar Membrane leads (St. Jude Medical Co.).…”
Section: Pacing System and Study Designmentioning
confidence: 99%
See 2 more Smart Citations
“…The study was designed to calculate the bat tery current drain and device longevity by evalu ating pacing output during long-term follow-up of a group of patients who had received a Microny SR+ 2425T W I R pacemaker, a single chamber rate modulated (SSIR) pulse generator (0.35 Ah battery capacity) with Autocapture as a pro-grammable option used for automatic adaptation of device output to stimulation threshold and con sistent ventricular capture. 3,4 All patients had also received low polarization, low threshold bipolar Membrane leads (St. Jude Medical Co.).…”
Section: Pacing System and Study Designmentioning
confidence: 99%
“…1,2 To improve pulse generator longevity, pacing systems capable of monitoring ventricular capture, and au tomatically adjusting the output to correct for tran sient loss of capture, have been recently de signed. 3,4 However, because of the risk of transient changes in stimulation threshold due to metabolic and pharmacological factors, 5 maintenance of ef fective ventricular cardiac stimulation is an obvi ous requirement to guarantee patient safety.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This provides considerable energy saving and prolongs the longevity of the pulse generator, because the pulse amplitude is one of the major determinant of the pulse generator's service life. 1 The efficacy and safety of Autocapture have been demonstrated in many clinical studies. [1][2][3][4][5] The pacemaker manufacturer recommends using a specifically designed, low polarization, low threshold, bipolar leads to avoid confusion between the polarization artifact and the ER signal.…”
Section: Introductionmentioning
confidence: 99%
“…1 The efficacy and safety of Autocapture have been demonstrated in many clinical studies. [1][2][3][4][5] The pacemaker manufacturer recommends using a specifically designed, low polarization, low threshold, bipolar leads to avoid confusion between the polarization artifact and the ER signal. 6 The aim of the study was to examine the com-patibility of the Autocapture pacing system to previously implanted endocardial pacing leads in children and young adults who required pulse generator replacement.…”
Section: Introductionmentioning