2017
DOI: 10.1063/1.4973060
|View full text |Cite
|
Sign up to set email alerts
|

Justification of the necessity to harmonize Russian and international standards concerning the determination of allowable VST immersion

Abstract: Abstract. The article analyzes the requirements of national and international regulatory documents for allowable dimensions of local subsidence (immersion) of the central part of the vertical storage tank (VST) bottom in order to establish more realistic requirements for tank steel structures that will reflect the real character of the VST bottom central part deformation. Analytical solutions for the problem of elastic deformation of a flexible membrane on the subsoil base and numerical simulation based on fin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…The model considers the work of the main structural elements of the VST: wall, annular plate, support stiffening ring, roof beams, sheet roofing, foundation ring. The junction of the wall, the annular plate and the foundation ring is modeled considering the results obtained in [14].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The model considers the work of the main structural elements of the VST: wall, annular plate, support stiffening ring, roof beams, sheet roofing, foundation ring. The junction of the wall, the annular plate and the foundation ring is modeled considering the results obtained in [14].…”
Section: Methodsmentioning
confidence: 99%
“…If the uneven tank subsidence exceeds the allowable value by the normative document [3,13], the method of repair is severely regulated -the method of lifting the tank with the help of jacks is used (Figure 1). However, this does not consider the history of loading the VST over the entire life cycle, the nature of uneven subsidence [14,15,16]. So, uneven subsidence can inherently result from defective construction and installation works, design errors, and can appear under the action of cyclic operational loads.…”
Section: Introductionmentioning
confidence: 99%
“…This allowed calculating with a high accuracy the overall stress-strain state of the tank during lifting operations. Solutions of such problems are discussed in [8,9,10,11,12,13,14,15,16].…”
Section: Introductionmentioning
confidence: 99%
“…An important problem is that the storage tanks constructed according to Russian and western standards have some differences in terms of design and materials [11]. In turn, this affects the overall stiffness of the structure, which determines the deformation behavior of the VST shell in case of uneven settlement.…”
Section: Introductionmentioning
confidence: 99%