2011
DOI: 10.1016/j.jelechem.2011.09.012
|View full text |Cite
|
Sign up to set email alerts
|

Kinetics and mechanism of palladium electrodeposition on graphite electrode by impedance and noise measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 75 publications
(25 citation statements)
references
References 59 publications
1
23
0
1
Order By: Relevance
“…The PZC has lowest capacitance value in variation of double layer capacitance versus applied anodic and cathodic potentials. Fitting of experimental impedance spectroscopy data to the proposed equivalent circuit was done by means of home written least square software based on Marquardt method for the optimization of functions and Macdonald weighting for the real and imaginary parts of the impedance [14,15].…”
Section: Apparatus and Methodsmentioning
confidence: 99%
“…The PZC has lowest capacitance value in variation of double layer capacitance versus applied anodic and cathodic potentials. Fitting of experimental impedance spectroscopy data to the proposed equivalent circuit was done by means of home written least square software based on Marquardt method for the optimization of functions and Macdonald weighting for the real and imaginary parts of the impedance [14,15].…”
Section: Apparatus and Methodsmentioning
confidence: 99%
“…Electrochemical impedance spectroscopy (EIS) measurements were performed in the frequency interval of 100 kHz to 1 mHz with AC amplitude of ±10 mV. Fitting of experimental impedance spectroscopy data to the proposed equivalent circuit was done by means of a home written least square software based on the Marquardt method for the optimization of functions and Macdonald weighting for the real and imaginary parts of the impedance [11,12].…”
Section: Methodsmentioning
confidence: 99%
“…A frequency sweep from 100 kHz to 10 MHz was used for EIS measurements. EIS data were curve-fitted to the proposed equivalent circuit by in-house least square software based on the Marquardt method for the optimization of functions and Macdonald weighting for the real and imaginary parts of the impedance [26,27]. SEM (VEGA, TESCAN-LMU) equipped with EDS was employed to characterize the surface morphology and average chemical composition.…”
Section: Methodsmentioning
confidence: 99%