“…Indeed, cuff pressures outside the target range are common, [27][28][29] and the frequency with which cuff pressure is measured and adjusted varies from never to at most every 8 hours. [30][31][32][33] Additionally, cuff pressure is often evaluated by using finger palpation. 30 Several investigators [34][35][36] have reported the inability of clinicians to adequately estimate cuff pressure by using finger palpation, and this practice generally results in excessive pressures.…”
Section: Acknowledgmentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Indeed, cuff pressures outside the target range are common, [27][28][29] and the frequency with which cuff pressure is measured and adjusted varies from never to at most every 8 hours. [30][31][32][33] Additionally, cuff pressure is often evaluated by using finger palpation. 30 Several investigators [34][35][36] have reported the inability of clinicians to adequately estimate cuff pressure by using finger palpation, and this practice generally results in excessive pressures.…”
Section: Acknowledgmentsmentioning
confidence: 99%
“…[30][31][32][33] Additionally, cuff pressure is often evaluated by using finger palpation. 30 Several investigators [34][35][36] have reported the inability of clinicians to adequately estimate cuff pressure by using finger palpation, and this practice generally results in excessive pressures. Monitoring cuff pressure via a manometer results in fewer complications after incubation.…”
Section: Acknowledgmentsmentioning
confidence: 99%
“…Kito tyrimo (2015) metu apie trečdalis Intensyvios terapijos slaugytojų nurodė palaikantys slėgį manžetėje 25 mmHg (36 proc.) ir 30 mmHg ( 32 proc) [24]. Mūsų tyrimo metu slaugytojų grupėje, kurie turėjo universitetinį išsimokslinimą, po mokymo reikšmingai didesnė dalis nurodė tracheostomos manžetės slėgį 15-25 cmH 2 O. Atliktų tyrimų rezultatai teigia, kad mažas endotrachėjinio vamzdelio manžetės slėgis (<15 mmHg) didina mikroaspiracijos ir ventiliacinės pneumonijos riziką [6,9,11,18], didelis endotrachėjinio vamzdelio slėgis (>30-35 mmHg) -didina trachėjos sienelės pažeidimo riziką [6].…”
Section: Diskusijaunclassified
“…Kito tyrimo (2015) rezultatai atskleidė, kad dauguma (76 proc.) ITS slaugytojų vamzdelio manžetės slėgį matuoja manometru [24]. Mūsų tyrimo metu po mokymo statistišk -kai reikšmingai daugiau slaugytojų (44,4 proc.)…”
Section: Diskusijaunclassified