1995
DOI: 10.1016/s0338-9898(95)80111-1
|View full text |Cite
|
Sign up to set email alerts
|

L'antibiogramme des bactéries anaérobies stricts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 36 publications
0
4
0
Order By: Relevance
“…Furthermore, anaerobic pathogens display higher variability of MIC and zone diameters when compared to aerobes and results are therefore more difficult to interpret (Dubreuil, 2020). Here, susceptibility testing of periodontal pathogens was performed by disc diffusion and interpreted according to the recommendations effective in the study period [summarized in (Dubreuil, 1995)]. Importantly, under EUCAST the methodology remains under development because standardization and, in particular interlaboratory reproducibility of breakpoints, is a major difficulty (Nagy et al, 2018; Dubreuil, 2020).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Furthermore, anaerobic pathogens display higher variability of MIC and zone diameters when compared to aerobes and results are therefore more difficult to interpret (Dubreuil, 2020). Here, susceptibility testing of periodontal pathogens was performed by disc diffusion and interpreted according to the recommendations effective in the study period [summarized in (Dubreuil, 1995)]. Importantly, under EUCAST the methodology remains under development because standardization and, in particular interlaboratory reproducibility of breakpoints, is a major difficulty (Nagy et al, 2018; Dubreuil, 2020).…”
Section: Discussionmentioning
confidence: 99%
“…However, extrapolation to breakpoints used for interpretation in agar dilution and E‐test is not possible. Interpretation of zone diameters was further limited to differentiation of ‘susceptible’ from ‘non‐susceptible’ isolates, following the French guidelines effective in the study period (Dubreuil, 1995). Notably, resistance may have been underestimated because very recent methodological studies define areas of technical uncertainty (ATU) that lie beyond the zone diameters used formerly to avoid very major errors and major errors, for example, an ATU of 17–20 mm was defined for amoxicillin‐clavulanate (Dubreuil, 2020).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations