2021
DOI: 10.1007/s00604-020-04697-7
|View full text |Cite
|
Sign up to set email alerts
|

Label-free colorimetric assay for arsenic(III) determination based on a truncated short ssDNA and gold nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(3 citation statements)
references
References 40 publications
0
3
0
Order By: Relevance
“…Gold nanoparticles (AuNPs) were synthesized by citrate (23,24). A 2% chloroauric acid solution (200 mL) was boiled under stirring conditions, and 6 mL of 2% trisodium citrate solution was quickly added.…”
Section: Detection Of Hla-g Based On Aunps-aptamer Sensing Methodsmentioning
confidence: 99%
“…Gold nanoparticles (AuNPs) were synthesized by citrate (23,24). A 2% chloroauric acid solution (200 mL) was boiled under stirring conditions, and 6 mL of 2% trisodium citrate solution was quickly added.…”
Section: Detection Of Hla-g Based On Aunps-aptamer Sensing Methodsmentioning
confidence: 99%
“…Electrochemical detection of As(III) using linker‐Free Magnetite‐decorated Gold Nanoparticles (Fe 3 O 4 ‐Au) has a range of detection of 1–100 μg/L and a detection limit of 0.22 μg/L (Sedki et al., 2021). Detection of As(III) using a label‐free colorimetric assay based on gold nanoparticles and truncated short ssDNA having a range of detection of 1–30 μg/L and 30–100 μg/L with a detection limit of 0.18 μg/L (Zhang et al., 2021). The different biosensor mechanisms for the detection of arsenic have been described in Exhibit 9.…”
Section: Detection Of Arsenic In An Aqueous System Using Biosensormentioning
confidence: 99%
“…To date, many rapid detection technologies have also been applied to the detection of As(III) ions, including antibody antigen immunoassay technology, 19 aptamer technology 18,20 and ion imprinting recognition detection technology. 21,22 Among them, ion imprinting technology (IIT), which is based on the use of the target substance as a template to form a similar lock-key structure through the combination of a monomer and cross-linking agent, 23 has been proved as a feasible method because of its specific imprinting cavities and strong selective adsorption for target ions compared with the other two methods, 24 and it can be sufficiently used in the rapid detection, adsorption and pretreatment of heavy metal ions.…”
Section: Introductionmentioning
confidence: 99%