1965
DOI: 10.1016/0020-708x(65)90010-4
|View full text |Cite
|
Sign up to set email alerts
|

Labeled oxygen difluoride—O17,18

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

1986
1986
2019
2019

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 2 publications
0
9
0
Order By: Relevance
“…These laser-ablated metal atoms were codeposited with 3–4 mmol of argon (Matheson, research grade) containing 1.0 or 2.0% OF 2 (Ozark–Mahoning) onto a CsI cryogenic window for 60 min. The 18 OF 2 sample (91% 18 O enriched) was synthesized and kindly provided by Arkell and co-workers . Both OF 2 and 18 OF 2 samples were used without further purification in a passivated stainless-steel vacuum manifold.…”
Section: Experimental and Computational Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…These laser-ablated metal atoms were codeposited with 3–4 mmol of argon (Matheson, research grade) containing 1.0 or 2.0% OF 2 (Ozark–Mahoning) onto a CsI cryogenic window for 60 min. The 18 OF 2 sample (91% 18 O enriched) was synthesized and kindly provided by Arkell and co-workers . Both OF 2 and 18 OF 2 samples were used without further purification in a passivated stainless-steel vacuum manifold.…”
Section: Experimental and Computational Methodsmentioning
confidence: 99%
“…The 18 OF 2 sample (91% 18 O enriched) was synthesized and kindly provided by Arkell and coworkers. 20 Both OF 2 and 18 OF 2 samples were used without further purification in a passivated stainless-steel vacuum manifold. FTIR spectra were recorded at 0.5 cm −1 resolution on a Nicolet 750 FTIR instrument with a HgCdTe range B detector.…”
Section: ■ Introductionmentioning
confidence: 99%
“…These laser-ablated metal atoms were codeposited with 3–4 mmol of argon (Matheson, research) containing 1.0% OF 2 (Ozark-Mahoning) onto a CsI cryogenic window for 60 min. The 18 OF 2 sample (91% 18 O enriched) was synthesized and kindly provided by Arkell and co-workers . Both OF 2 and 18 OF 2 samples were cooled to 77 K using liquid N 2 and evacuated to remove residual N 2 and O 2 before use.…”
Section: Experimental and Computational Methodsmentioning
confidence: 99%
“…These OF 2 sample (91% 18 O enriched) was synthesized and kindly provided by Arkell and co-workers. 21 Both OF 2 and 18 OF 2 samples were cooled to 77 K using liquid N 2 and evacuated to remove residual N 2 and O 2 before use. Fourier transform infrared (FTIR) spectra were recorded at 0.5 cm −1 resolution on a Nicolet 750 FTIR instrument with a HgCdTe range B detector.…”
Section: ■ Introductionmentioning
confidence: 99%
“…The 18 OF 2 sample (91% 18 O enriched) was synthesized and kindly provided by Arkell and Reinhard. 22 Both OF 2 and 18 OF 2 samples were used without further purification in a passivated stainless steel vacuum manifold. Complimentary experiments were performed ablating solid titanium(II) oxide (Strem Chemicals, Inc.) into 1% F 2 /argon samples using our dedicated, passivated stainless steel manifold for fluorine.…”
Section: Experimental and Theoretical Methodsmentioning
confidence: 99%